1-24 (No.49839)
SECTION 3
Adjustment
3.1
Adjustment method
Test instruments required for adjustment
(1) Digital oscilloscope (100MHz)
(2) AM Standard signal generator
(3) FM Standard signal generator
(4) Stereo modulator
(5) Electric voltmeter
(6) Digital tester
(7) Tracking offset meter
(8) Test Disc JVC :CTS-1000
(9) Extension cable for check
EXTSH002-22P
×
1
Standard volume position
Balance and Bass &Treble volume : lndication"0"
Loudness : OFF
Standard measuring conditions
Frequency Band
Dummy load
Exclusive dummy load should be used for AM,and FM. For FM
dummy load,there is a loss of 6dB between SSG output and
antenna input.The loss of 6dB need not be considered since
direct reading of figures are applied in this working standard.
How to connect the extension cable for adjusting
Caution:
Be sure to attach the heat sink and rear bracket onto the power amplifier IC and regulator IC respectively, before supply the power.
If voltage is applied without attaching these parts, the power amplifier IC and regulator IC will be destroyed by heat.
Power supply voltage
DC14.4V(11 to 16V)
Load impedance
20K
Ω
(2 Speakers connection)
Output Level
Line out 2.0V (Vol. MAX)
FM
87.5MHz to 107.9MHz
(with channel interval set to 200kHz)
87.5MHz to 108.0MHz
(with channel interval set to 50kHz)
AM
530kHz to 1710kHz
(with channel interval set to 10kHz)
531kHz to 1602kHz
(with channel interval set to 9kHz)
The cardboard is cut in a suitable size.
uses for the insulation stand of mechanism.
EXTSH002-22P
Extension cable
Heat sink
(Attach the heat sink
using the two screws.)
Rear bracket
(Attach the rear bracket
using the screw.)
Front chassis assembly
(Attach the front chassis assembly using the two screws.)
Содержание KD-LH3105