•As the Transformer discharges, the Secondary Windings
develop secondary voltages
•The DC Voltage supplying the Switching IC becomes
insufficient.
•As the Capacitor discharges the Switching IC requires
additional voltage to maintain stable operation.
•Additional Run-DC is provided to the Switching IC from the
Transformers Secondary.
•This Voltage maintains the ICs continuous operation and the
Circuit becomes stable.