• When power is turned on, the Run-DC is sufficient to keep
the IC functioning.
• During Standby Mode the Output Voltages from the
Transformer is reduced.
• When this happens, the IC could turn off due to the
insufficient Run-DC Voltage that is being supplied.
• For this reason, a regulated DC voltage from a higher tap is
used to supplement the RUN DC.
•This voltage must be regulated otherwise in normal operation
the voltage will be too high and will destroy the IC
This circuit is not used in all models