This is start up circuit. This circuit composes R911, R930, D911 and C914.
•This circuit Provides the Start-up Voltage for the Switching IC911
•The DC voltage supplied by this circuit turns the IC and FET ON.
•If the IC was open and AC current was allowed to flow, no current would flow
through the IC. This would cause C914 to overcharge and explode.
For this
reason, If you find a defective Switching Regulator IC, replace the
Capacitor. Similarly, if you find exploded Capacitor, replace the IC.
Reference Schematic 52004 Main PWB for Schematic Details.
Содержание I'Art AV-27MF36
Страница 1: ...JVC Television Power Supply Training ...
Страница 5: ...TELEVISION MODEL IDENTIFICATION ...
Страница 56: ...SWITCH CIRCUIT REVIEW TELEVISION We will quickly go through the operation of a Switching Supply ...
Страница 75: ...MC33262D X TELEVISION POWER FACTOR IC ...
Страница 84: ...FUNCTION CHECK PROCEDURE INSPECT PWB TELEVISION BROKEN SHORTED MISSING COMPONENT NOT FULLY INSERTED ...
Страница 94: ...FUNCTION CHECK PROCEDURE BATTERY TESTING DEVICE TELEVISION _ _ _ _ ...
Страница 103: ...TROUBLESHOOTING RELAY FUNCTION CHECK TELEVISION Use this circuit to test the Relay Follow Steps to assist ...
Страница 105: ...TROUBLESHOOTING REGULATOR CHECK TELEVISION Use this circuit to test the Regulators Follow Steps to assist ...