12. SETUP MENU
81
Item
Function, Operation
Variation Range
Initial Setting
COLOR
MATRIX
GAMMA
SKIN COLOR
ADJUST
PAGE BACK
Sets the color matrix
OFF ...... Deactivates the color matrix function
ON ....... The color reproducibility is enhanced, but noise increases.
During the LOLUX operation, COLOR MATRIX is fixed to the OFF
setting and "FIX" is displayed.
Correction of the gamma curve to decide the reproducibility of black color.
• To enhance the black color reproducibility. However, halftones will be
lost for white section
............... Increase the number
• When reproducibility of the black color is not so important
............... Decrease the number
• During LOLUX operation or setting GAIN to 18 dB, "FIX" is displayed
because GAMMA is fixed at the MIN value.
Pressing the SHUTTER dial once when the cursor is at this position
switches the screen to display the SKIN COLOR ADJUST screen.
The PROCESS MENU returns when the SHUTTER dial is pressed with
the cursor at this position.
ON
OFF
MAX (8)
7
18
gradations
to
NORMAL (0)
to
-7
MIN (-8)
OFF
–
ON
NORMAL
–
Item
Function, Operation
Variation Range
Initial Setting
SKIN COLOR
DETECT
SKIN COLOR
RANGE
PAGE BACK
Sets whether it is possible to change the color used by the Skin Tone
Detail function.
EXECUTE ...... Choose this setting to allow detection of the color used by
the Skin Tone Detail function.
STOP ............. Choose this setting to stop detection of the color used by
the Skin Tone Detail function.
☞
See "Using the Skin Tone Detail Function" on page 91.
The setting of this item can only be changed when the SKIN COLOR
DETECT item is set to EXECUTE.
This setting is for adjusting the skin color range where Skin Tone Detail
functions. (When this item is selected, the area where the Skin Tone Detail
function is applicable is indicated by zebra patterns on the screen.)
While viewing the zebra pattern range, perform the adjustment.
Increasing the range ........ Increase the number
Increasing the range . ...... Decrease the number
The ADVANCED PROCESS MENU returns when the SHUTTER dial is
pressed with the cursor at this position.
STOP
EXECUTE
WIDE
+19
(33 gradations)
to
NORMAL
to
-11
NARROW
–
STOP
NORMAL
–
12-8 SKIN COLOR ADJUST Screen
12-7 ADVANCED PROCESS Screen
CAUTION:
CAUTION: