RS-485 IN
RS-485
OUT
RS-485
IN
RS-485
OUT
RS-485
IN
RS-485
OUT
TallyMan
They are female terminals.
Serial connections:
RS485 IN
ETHERNET
RS485 OUT
Pin No
Pin name
1
TX+
2
TX-
3
RX+
4
5
6
RX-
7
8
Pin No
IN terminal signal
OUT terminal signal
1
TXD+
TXD+
2
TXD-
TXD-
3
RXD+
RXD+
4
NC
NC
5
NC
NC
6
RXD-
RXD-
7
NC
NC
8
GND
GND
Use crossed wired cable for computer-monitor directly
connection.
Use straight-through wired cable for Router connection.
Please seek help from your webmaster for any network
connections.
Monitor IP address
Monitor port address
2) Launch any of a web browser on the computer, and enter URL:
Monitor IP + port (for example 192.168.1.99:8080). The webserver
control page will be displayed.
18
*2 UMD control
Select UMD mode to “External” will enable TSL UMD control.
TallyMan system connection:
*3 Webserver IP Control
Connect the monitor ETHERNET port into LAN, and the monitor can
be remote controlled by webpage.
Enter Menu- External Control - IP/Net Mask/Gateway/Port to
set the monitor addresses.
Set the computer Ethernet IP address at the same LAN
environment as the Monitor.