(No. YA104) 1-25
Item
Measuring
instrument
Test point
Adjustment part
Description
V. HEIGHT
adjustment
[4. DEF]
3. V-SIZE
14. V-ZOOM
- PAL V. HEIGHT -
(1) Receive a PAL crosshatch signal.
(2) Select
3. V-SIZE
.
(3) Set the initial setting value of
3. V-SIZE
.
(4) Select
14. V-ZOOM
.
(5) Set the initial setting value of
14. V-ZOOM
.
(6) Adjust
14. V-ZOOM
to make the vertical screen size to
92% of the picture size.
- NTSC V. HEIGHT -
(1) Receive a NTSC crosshatch signal.
(2) Make similar adjustment of NTSC V. HEIGHT in the same
way as for “PAL V. HEIGHT”.
Signal
generator
Remote
control unit
H. POSITION
adjustment
- PAL H. POSITION -
(1) Receive a PAL circle pattern signal.
(2) Select
4. H-CENT
.
(3) Set the initial setting value of
4. H-CENT
.
(4) Adjust
4. H-CENT
to make “
C = D
”.
- NTSC H. POSITION -
(1) Receive a NTSC circle pattern signal.
(2) Make similar adjustment of NTSC H. POSITION in the
same way as for “PAL H. POSITION”.
Signal
generator
Remote
control unit
H. WIDTH
adjustment
[4.DEF]
5. H-SIZE
- PAL H. WIDTH -
(1) Receive a PAL crosshatch signal.
(2) Select
5. H-SiZE
.
(3) Set the initial setting value of
5. H-SIZE
.
(4) Adjust
5. H-SIZE
to make the horizontal screen size to
91% of the picture size.
- NTSC H. WIDTH -
(1) Receive a NTSC crosshatch signal.
(2) Make similar adjustment of NTSC H. WIDTH in the same
way as for “PAL H. WIDTH”.
Signal
generator
Remote
control unit
Screen size 91%
Picture size 100%
Screen
size
92%
Picture
size
100%
C
D
[4. DEF]
4. H-CENT