No. 51945
AV32H20EUS
AV28H20EUS
AV28H20EUB
30
AUDIO CIRCUIT ADJUSTMENT
"
Do
not
touch
3. AUDIO
adjustment of the SERVICE MENU as it requires no adjustment.
If values had changed for the some reas on, set the initial values in the following table.
3. AUDIO (Do not adjust)
Setting item
Variable range
fixed value
1. ERR LIMIT
000H
~
FF0H
100H
2. A2 ID THR
00H
~
FFH
19H
3. Q-PEAK
0000H
~
7FFFH
---