No. 51945
AV32H20EUS
AV28H20EUS
AV28H20EUB
22
Item
Measuring
instrument
Test point
Ad justment part
Description
7.COLOUR
(PAL
~
~
~
~
NT SC)
[Method of adjustment without measuring instrument]
PAL COLOUR
(PAL COLOUR)
1. Receive PAL broadcast.
2. Select 2.V/C from the SERVICE MENU.
3. Select 7.COLOUR with the FUNCTION UP/DOWN ( / ) key.
4. Set the initial setting value for PAL COLOUR with the
FUNCTION - or + ( / ) key.
5. If the colour is not the bes t with the initial set value, make
fine adjustment until you get the best colour.
6. Press the MENU key and memoriz e the s et value.
SECAM COLOUR
(SECAM COLOUR)
1. Receive a SECAM broadc ast.
2. Make fine adjustment of SECAM COLOUR in the s ame
manner as for above.
(NTSC 3.58 COLOUR)
1. Input a NTSC 3.58MHz COMPOSITE VIDEO signal from the
EXT terminal.
2. Make similar fine adjustment of NT SC 3.58 COLOUR in the
same manner as for above.
S UB CO LO UR
Ⅰ
Ⅰ
Ⅰ
Ⅰ
adjustment
Remote
control unit
NTSC COLOUR
(NTSC 4.43COLOUR)
1. When NTSC 3.58 COLOUR set, NTSC 4.43 COLOUR will
automatic ally set.
REMOTE CONTROL KEY
CH.
key
MENU
( OK ) k ey
FUNCTION
key
(
INFORMATION
) key
i