No. 52005
AV-27F703
AV-27F713
AV-27F803
23
ADJUSTMENT OF RF AGC
Item
Measuring
instrument
Test point
Ad justment part
Description
RF. AGC
adjustment
S45:AGC ADJ
1. Receive a black and white signal (color off).
2. Select
S45:AGC ADJ
of the V/C MODE.
3. Press the MUTING key and turn off c olor.
4. With the FUNCTION key to get the noise in the screen
picture (zero s ide of s etting value).
5. Press the FUNCTION key several times and step when
nois e dis appears from the screen ( at that time, not to increas e
the value too much).
6. Change to other c hannels and mak e sure that there is no
irregularity.
7. Press the MUTING key and get color out.
ADJUSTMENT OF FOCUS
Item
Measuring
instrument
Test point
Ad justment part
Description
FOCUS
adjustment
Signal
generator
FOCUS VR
[In HVT]
1. Receive the cross-hatch signal.
2. While looking at the screen, adjust the FOCUS VR to the
vertical and horizontal lines will be thinnest and s harpest
center horizontal line.
3. Make sure that the picture is in focus even when the screen
gets darkened.
ADJUSTMENT OF DEFLECTION CIRCUIT
Item
Measuring
instrument
Test point
Ad justment part
Description
V. HEIGHT
V. CENTER
adjustment
(4:3)
Signal
generator
D05:V PHASE
D07:V SIZE
V. CENTER SW
(S1421)
[MAIN PWB]
1. Receive the cross -hatch signal.
2. Enter the SERVICE MENU.
3. Select
the
D05:V PHASE
of the 2.DEF (D) item, and it c hecks
that the value of
D05:V PHASE
is
0
.
4. Adjust the vertical screen size of the visible screen top to
90.0% with the
D07:V SIZE
and
V CENTER SW S1421.
*
Bottom is to be loc ated with 85%
~
95% range.
*
It adjust it by DEF SERVICE
D13: V LIN.
And
D11: VS CORR.
when vertical linearity is not even.
No .
Setting item
Variable
range
Initial setting
value
S45
AGC ADJ
0
~
127
63
Picture
size
(100%)
Picture size (100%)
Screen
size
(90.0%)
Screen size
No .
Setting item
Variable
range
Initial setting
value
D05
V PHASE
0
~
7
00
D07
V SIZE
0
~
127
75