No. 52005
AV-27F703
AV-27F713
AV-27F803
22
■
ADJUSTMENTS
B1 POWER SUPPLY
Item
Measuring
instrument
Test point
Ad justment part
Description
Check of
B1 POWER
SUPPLY
DC Voltmeter
【
【
【
【
B1
】
】
】
】
Connector
(pin1 & pin3)
TP-91(pin1)
TP-E(
#
):(pin3)
1. Receive the blac k-and-white signal. (color off)
2. Connect the DC voltmeter to
【
B1
】
connector pin
【
1
】
(TP-91)
and TP-E(
#
) (B1 connector pin
【
3
】
).
3. Confirm that the voltage is DC134.5V
±
2V.
ADJUSTMENT OF VCO
Item
Measuring
instrument
Test point
Ad justment part
Description
MAIN VCO
adjustment
Signal
generator
10:VCO MAIN
CW TRANSF.(T111)
[MAIN PWB]
"
It mus t not adjust without signal
1. Receive color bar signal.
2. Enter the SERVICE MENU mode.
3. Press the
▲
key, and s elect the 10:VCO mode from the
SERVICE MENU.
4. Push the FUNCTION / key, and s elect MAIN.
5. Confirm that the color change from
HIGH LEVEL
to
LOW
LEVEL
by CW TRANSF T111 at MAIN PWB, and check the
SYNC : YES
.
6. Adjust
until
REFERENCE LEVEL
mark turns green.
And then confirm that the
SYNC : YES
again.
7. Press the EXIT key to get out SERVICE MENU.
SUB VCO
adjustment
(AV-27F803 ONLY)
Signal
generator
10:VCO
"
It mus t not adjust without signal
1. Receive color bar signal.
2. Enter the SERVICE MENU mode.
1. Press the FUNCTION (
▲
)
key, and s elect the 10:VCO mode
from the SERVICE MENU.
4. Push the left / right ( / ) key, and s elect SUB.
5. Confirm that the change from
HIGH LEVEL
to
LOW
LEVEL
by
CW transformer T4111 at PIP PWB, and c heck the
SYNC :
YES
.
6. Adjust
until
REFERENCE LEVEL
mark turns green.
And then confirm that the
SYNC : YES
again.
7. Press the EXIT key to get out SERVICE MENU screen.
TUNER
MAIN
HIGH LEVEL
REFERENCE LEVEL
LOW LEVEL
SYNC :
YES
GREEN
TUNER
SUB
HIGH LEVEL
REFERENCE LEVEL
LOW LEVEL
SYNC :
YES
GREEN