AV-27D104 AV-27D304
AV-27430 AV-27432
1-24 (No.52102)
3.6.7
MTS CIRCUIT
Item
Measuring
instrument
Test point
Adjustment part
Description
MTS INPUT
LEVEL
Remote
control unit
[3.SOUND(A)]
A01 : IN LEVEL
(1) Select the <A01>(IN LEVEL) of the 3.SOUND.
(2) Verify that the <A01> is set at its initial setting value.
MTS
SEPARATION
TV audio
multiplex
signal
generator
Oscilloscope
Remote
control unit
R OUT
L OUT
[AUDIO OUT]
[3.SOUND(A)]
A06 : LOW SEP
A07 : HI SEP
(1) Input the stereo L signal (300Hz) from the TV audio
multiplex signal generator to the antenna terminal.
(2) Connect an oscilloscope to R OUT pin of the AUDIO
OUT, and display one cycle portion of the 300Hz
signal.
(3) Select the <A06>(LOW SEP) of the SOUND MODE.
(4) Set the initial setting value of the <A06> with the
[VOLUME (-/+)] key.
(5) Adjust the <A06> so that the stroke element of the
300Hz signal will become minimum.
(6) Change the connection of the oscilloscope to L OUT
pin of the AUDIO OUT, and enlarge the voltage axis.
(7) Change the signal to 3kHz, and similarly adjust the
<A07>(HI SEP).
No.
A01
Setting item
IN LEVEL
0
㨪
63
036
Variable
range
Initial setting
value
L-Channel
signal waveform
R-Channel
crosstalk portion
Minimum
1 cycle
No.
A06
Setting item
LOW SEP
0
㨪
63
008
A07
HI SEP
0
㨪
63
026
Variable
range
Initial setting
value