AV-27D104 AV-27D304
AV-27430 AV-27432
1-22 (No.52102)
SUB COLOR
Signal
generator
Oscilloscope
Remote
control unit
TP-B
TP-E
[CRT SOCKET
PWB]
[1.V/C(S)]
S03 : COLOR
[ Method of adjustment without measuring instrument ]
(1) Receive the broadcast.
(2) Select <S03>(COLOR) of the 1.V/C(S).
(3) Set the initial setting value of the <S03> with the
[VOLUME (-/+)] key.
(4) If the color is not the best with the Initial setting
value, make fine adjustment of the <S03> until you
get the optimum color.
[ Method of adjustment using measuring instrument ]
(1) Receive the full field color bar signal (75% white).
(2) Select <S03>(COLOR) of the 1.V/C(S).
(3) Set the initial setting value of the <S03> with the
[VOLUME (-/+)] key.
(4) Connect the oscilloscope between TP-B and TP-E.
(5) Adjust <S03> and bring the value of (A) in the
illustration to the voltage given in the below table.
Item
Measuring
instrument
Test point
Adjustment part
Description
W
B
0V
(-)
(+)
(A)
Y
C
G
M
R
No.
S03
Setting item
COLOR
0
㨪
127
64
Variable
range
Initial setting
value
W-B
SA model
RA model
+15V
+17V
Adjustment Voltage
Models