AV-27D104 AV-27D304
AV-27430 AV-27432
(No.52102)1-23
SUB TINT
Signal
generator
Oscilloscope
Remote
control unit
TP-B
TP-E
[CRT SOCKET
PWB]
[1.V/C(S)]
S04 : TINT
[ Method of adjustment without measuring instrument ]
(1) Receive the broadcast.
(2) Select <S04>(TINT) of the 1.V/C.
(3) Set the initial setting value of the <S04> with the
[VOLUME (-/+)] key.
(4) If the tint is not the best with the initial setting value,
make fine adjustment of the <S04> until you get the
optimum tint.
[ Method of adjustment using measuring instrument ]
(1) Receive the full field color bar signal (75% white).
(2) Select <S04>(TINT) of the 1.V/C.
(3) Set the initial setting value of the <S04> with the
[VOLUME (-/+)] key.
(4) Connect the oscilloscope between TP-B and TP-E.
(5) Adjust <S04> and bring the value of (B) in the
illustration to the voltage given in the below table.
Item
Measuring
instrument
Test point
Adjustment part
Description
W
M
0V
(-)
(+)
(B)
Y
C
G
R
B
No.
S04
Setting item
TINT
0
㨪
127
64
Variable
range
Initial setting
value
W-B
SA model
RA model
+25V
+20V
Adjustment Voltage
Models