jurop PN 155 Скачать руководство пользователя страница 6

MAX. SPEED – OPERATING SPEED (RPM) 

P

2

(bar ABS)

T

2

 

(°C) 

T

2

- T

1

 

(°C) 

PN155 – PN155R 

M - 540 

PN155 – PN155R 

M - 1000 

PN155 D / PN155R D 

PN155 HDR / PN155R HDR 

Max Max Max 

540 - 470 

1000 - 900 

1150 - 1000 

2 * 

150°C 

130 

P

1

: absolute pressure during suction 

T

1

: temperature during suction 

P

2

: absolute pressure during delivery 

T

2

: temperature during delivery 

NOTE.

 

*

 Belt drive only for PN155 D and PN155R D: P

2

= 1,5 abs bars. 

Air flow (free

 

air 

condition) 

l/min 15200  

Vacuum at continuous 

duty

 

 

PN155 

60 % 

Air flow at 60% vac.  

l/min 

13500 

PN155 R 

70 % 

Max. vacuum 

93 

Oil consumption 

g/h 

250 

Power required at max. 

vacuum  

kW 

19 

Sound pressure level **

dB (A) 

79 

Power required at 2 abs 

bars pressure  

kW

23

Weight

kg

220

**

: only when decompressor at max. speed, 60% vacuum rate, 7 m distance in open field. 

Performances referred to decompressor operating at max. speed. 

REFERENCE CONDITIONS

Conveyed 

gas: 

air 

Functioning 

in 

free 

air. 

Reference abs. pressure: 1.013 mbar 

Reference temperature: 20°C 

Vacuum functioning: free outlet 

Pressure functioning: free inlet 

CAREFULLY OBSERVE THE FOLLOWING RULES 

When transporting the pump, use proper slinging. Store the pump in stable places.

Installation and maintenance must be operated only by qualified personnel wearing the proper clothes
and the necessary tools as well as protection devices.

Before each maintenance operation:

Stop the pump and restore the atmospheric pressure.

Disengage the drive system.

Only operate after the pump has cooled down.

When the pump is running, some parts may reach very high temperatures (above 100°C). Use all
necessary precautions to avoid contact.

Operators 

working 

nearby 

must avoid prolonged exposure to the noise emitted by the aspirator, if not

equipped with the proper ear-protection devices.

Avoid accidental suction of solids: solids may be projected at high speed through the exhaust manifold
and cause injures.

7. SAFETY AND ACCIDENTS PREVENTION

6. PERFORMANCES

5. USAGE LIMITATIONS

www.fraserwoods.ca

Содержание PN 155

Страница 1: ... R OPERATING AND MAINTENANCE INSTRUCTIONS Authorized Jurop Distributor Service Repair Facility 120 10293 276 ST Acheson Alberta Canada T7X 6A5 T 780 962 1827 F 780 962 1830 E sales fraserwoods ca www fraserwoods ca ...

Страница 2: ...e Belt drive Hydraulic drive Precautions when starting the system 10 OPERATING PRECAUTIONS 11 ORDINARY MAINTENANCE Checking the drip oilers Checking the side mounted tank oil level Checking the vanes wear Checking the gear box oil level 12 EXTRAORDINARY MAINTENANCE Adjusting the 4 way valve Replacing the vanes Adjusting the self lubricating pump 13 TROUBLESHOOTING 14 SCRAPPING 15 SPARE PARTS REQUE...

Страница 3: ... be acquainted with these instructions the booklet be kept in a place at hand known by all users In these instructions some graphic symbols are used to draw the attention to some particular operations If these safety rules are not respected operators can be injured and the pump or oilers damaged remarkably If these safety rules are not respected the pump or system can be damaged Suggestions for an...

Страница 4: ...509410 PN155R M 540 rpm left rotation A363209410 PN155R M 1000 rpm left rotation A363509410 PN155 HDR right rotation E3508109410 PN155R HDR right rotation E3608109410 HDR MOTOR FEEDING Motor Displacement cc rev Operating Pressure bar Max Flow l min 86 140 100 www fraserwoods ca ...

Страница 5: ...haft ASAE 1 3 8 left rotation Hydraulic drive with gear motor right rotation As model PN155 In addition Extra air injection cooling system High resistant vanes OTHER FEATURES ON REQUEST Rotation other than the standard one Pneumatic or hydraulic actuator for the 4 way valve The vacuum pump PN155 is designed to convey filtered air into systems for the vacuum production or for the suction of powders...

Страница 6: ...n free air Reference abs pressure 1 013 mbar Reference temperature 20 C Vacuum functioning free outlet Pressure functioning free inlet CAREFULLY OBSERVE THE FOLLOWING RULES When transporting the pump use proper slinging Store the pump in stable places Installation and maintenance must be operated only by qualified personnel wearing the proper clothes and the necessary tools as well as protection d...

Страница 7: ... in the silencer s separator at the exhaust and the oil used in the vacuum pump maintenance internal wash up or periodical replacement in the gear box as provided by current specifications Legend of main components A Multiplier gear box B Manifold C Vacuum pressure manifold D Non return valve E Vacuum relief valve connection F Oil tank G Oilers H Lubrication pump I Air injection valve J Swivelling...

Страница 8: ...2 Oilers 3 Oil tank level 4 Oil tank inlet plug 5 Oil tank outlet plug 6 Self lubricating pump 7 Gear box oil level 8 Gear box oil outlet plug 9 Gear box oil inlet plug 10 4 way valve handle 2 VACUUM PRESSURE LINE In order to avoid accidental suction of liquids inside the pump install a primary pos 1 and a secondary flow shutoffs pos 2 If necessary install also a suction filter pos 3 to protect fr...

Страница 9: ...optional components CARDAN SHAFT DRIVE Use telescopic cardan shafts In order to achieve a uniform motion of the driven shaft the following requirements must be met Equal working angle α and α1 of both couplings The internal fork joints must be coplanar Both driven and driving shafts must be coplanar It is also recommended working with limited articulated joint angles max 15 and disengaging the tra...

Страница 10: ...d 1 5 abs bars to prevent it from absorbing a power requiring an excessive belt tension There is no limit to the operation in vacuum Drive min pulley pitch diam Belts Max Speed Max Pressure Max Vacuum mm rpm bar abs 180 XPB x 3 1150 1 5 93 HYDRAULIC DRIVE Motor features Displacement Max operating pressure Max pressure draining line Max press motor exhaust cc rev bar bar bar 86 220 5 5 Fluid minera...

Страница 11: ...smission Tank with suction pipe and return separated by baffles If necessary use a heat exchanger to avoid oil heating above 70 80 C and protect it from extreme pressure with a pressure relief valve Minimum approximate capacity as twice as the circulation flow Starting up be sure that the system is well cleaned and pour oil into the tank and into the motor housing necessary to lubricate the intern...

Страница 12: ...s the suction port otherwise it will sack warm gas Control the air flow by adjusting the rotation speed do not use the pressure relief valve to discharge the exceeding flow Internal wash up is necessary after prolonged inactivity after working in dusty environments or in case of accidental suction of liquids Such operation must be carried out only on cooled pumps Disconnect the exhaust silencer if...

Страница 13: ...o the oilers Be sure it is regular app 35 drops min at max speed to grant a correct lubrication of the pump At lower speeds the number of drops must be directly proportional CHECKING THE SIDE MOUNTED OIL TANK LEVEL Do not run the pump with oil level under the minimum level that may lead to dry functioning and cause serious damages Tank capacity 4 litres Use pure fresh oil Do not re use the exhaust...

Страница 14: ...MOBIL BP ISO VG 220 EP mineral oil BLASIA 220 SPARTAN EP 220 OMALA OIL 220 REDUCTELF SP 220 MOBILGEAR 630 ENERGOL GR XP 220 Dispose of exhausted oil as provided by current specification When changing the oil also replace the outlet plug washer Before starting any extraordinary maintenance operation be sure the pump stands still and follow the safety prescriptions as described in paragraph Safety a...

Страница 15: ...mbly by forcing them exceedingly Do not flip the seal ring during rotation of the shaft Do not leave foreign objects inside the pump ADJUSTING THE SELF LUBRICATING PUMP The automatic lubricating pump is adjusted by the manufacturer before the shipping If consumption noticeably differs from the indicated value adjust it as follows Remove the upper protection cover Using a screwdriver and a 10 mm wr...

Страница 16: ...ove ice and slowly start running it Avoid suction of water Reduced performances Four way changeover valve in idle position Move the lever to vacuum or pressure mode end stroke Four way changeover valve not correctly registered Adjust the functioning play and lubricate Worn vanes Replace vanes The non return valve leaks Clean or replace if necessary Worn seal rings Replace Tank gate valves or gaske...

Страница 17: ... as spare parts To order spare parts give the following information Find in the parts list code name quantity Ex cod 1601606200 Vane 4 pz Find on the suction plate model serial number Es LC 420 H60013 14 SCRAPPING 15 SPARES PARTS REQUETING SPARE PARTS Authorized Jurop Distributor Service Repair Facility 120 10293 276 ST Acheson Alberta Canada T7X 6A5 T 780 962 1827 F 780 962 1830 E sales fraserwoo...