Safety Instructions 

Warning 

 

Do  not  use  means  to  accelerate  the  defrosting  process  or  to  clean,  other  than 

those recommended by the manufacturer. 

 

The appliance shall be stored in a room without continuously operating ignition 

sources  (for  example:  open  flames,  an  operating  gas  appliance  or  an  operating 

electric heater.) 

 

Do not pierce or burn. 

 

Be aware that refrigerants may not contain an odor. 

 

Appliance  shall  be  installed,  operated  and  stored  in  a  room  with  a  floor  area 

larger than 12.5 m

2

 

Keep any required ventilation openings clear of obstruction. 

 

Servicing shall be performed only as recommended by the manufacturer. 

 

The  appliance  shall  be  stored  in  a  well-ventilated  area  where  the  room  size 

corresponds to the room area as specified for operation. 

 

Any  person  who  is  involved  with  working  on  or  breaking  into  a  refrigerant 

circuit  should  hold  a  current  valid  certificate  from  an  industry-accredited 

assessment  authority,  which  authorizes  their  competence  to  handle  refrigerants 

safely in accordance with an industry, recognized assessment specification. 

 

Servicing  shall  only  be  performed  as  recommended  by  the  equipment 

manufacturer.  Maintenance  and  repair  requiring  the  assistance  of  other  skilled 

personnel shall be carried out under the supervision of the person competent in 

the use of flammable refrigerants. 

 

All  working  procedure  that  affects  safety  means  shall  only  be  carried  by 

competent persons. 

 

Be careful not to bump when moving to avoid leakage in the refrigeration line.

 

                                                           
 
 

Flammable material.                        Refer operators      Read technical     

Read operators

 

 

This appliance contains R290/              manual              manual   

Propane a flammable refrigerant   

Содержание Eco II 16L

Страница 1: ...Dehumidifier Instruction Manual Please keep this instruction manual for future potential usage...

Страница 2: ...al and keep it for potential usage Page Warnings 1 Working principle 2 Working environment 3 Important Safety Measures 4 Body of machine 5 Operation Method 6 7 Drainage 8 Maintenance 9 Storage 10 Prob...

Страница 3: ...must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Meaning of crossed out wheeled dustbin Do not dispose of electrical appliances as unsor...

Страница 4: ...r flows through the body of the evaporator and radiator and the relative humidity of the room could be controlled the excessive moisture air flow through the evaporator the air will condenses into wat...

Страница 5: ...you can set the room humidity according to requirement It could create a healthy and comfortable environment The machine usually used in basement wine cellar storage closet Also could be used in kitch...

Страница 6: ...he description in rating label 7 Don t plug unplug the machine to open close it and use the control panel 8 Before moving the machine you need to turn off it unplug and ensure the water tank is empty...

Страница 7: ...5 Body of Machine 1 Control panel 2 Air Inlet 3 Filter 4 Water Tank 5 Castor 6 Handle of water tank 7 Handle of machine 8 Air Outlet 9 Continuous Drainage Outlet...

Страница 8: ...t timing repeat pressing it to set auto shutting down at the range of 0 24 hours 0 excluded Starting timing timing indicator lights And when setting time out machine will be shut down automatically 2...

Страница 9: ...of the humidity display will lighting all the time and the compressor stops while the fan stills works Detection of full water When tank is full alarm buzzing corresponding indicator lights and machi...

Страница 10: ...placed in correct position 7 Continuous Drainage When machine should be worked for long time please refer as follows 1 Remove the rubber cap A on the continuous drainage outlet and take off the rubbe...

Страница 11: ...s optional accessories 1 Filter blocking dust Filter 1 Outer dust filter cleaning removing the grid then take off filter from the back of machine fig 4 2 Let dust off by a vacuum cleaner or brush it g...

Страница 12: ...does not run for long time please do as follows 1 Turn off machine cut off power and sort out power cord 2 Pour out tank water and wipe it 3 Clean the filter 4 Cover up machine and place it in one po...

Страница 13: ...Whether the filter is dusty or is contaminated Whether inlet or outlet is blocked Whether humidity indoor is too less Dehumidification effect is not obvious Whether you are opening too many windows o...

Страница 14: ...perature of heat exchanger rises suddenly leading to temporary strange smell or musty taste Machine echoes If machine used in a small room or a wooden floor room may echo At the start of operation mod...

Страница 15: ...he room area as specified for operation Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry accredited assessment...

Страница 16: ...r heat sources Don t disassemble overhaul and modify the machine arbitrarily otherwise it will cause a machine malfunction or even bring harm to persons and properties To avoid danger if a machine fai...

Страница 17: ...in order to avoid a hazard Transportation marking and storage for units 1 Transport of equipment containing flammable refrigerants Compliance with the transport regulations 2 Marking of equipment usi...

Страница 18: ...n is AC250V 3 15A Appliance is filled with flammable gas R290 and the maximum charge of refrigerant is 60g GWP value of R290 refrigerant is 3 Any repairs you need contact the nearest authorized Servic...

Страница 19: ...t detector prior to and during work to ensure the technician is aware of potentially flammable atmospheres Ensure that the leak detection equipment being used is suitable for use with flammable refrig...

Страница 20: ...b The ventilation machinery and outlets are operating adequately and are not obstructed c If an indirect refrigerating circuit is being used the secondary circuit shall be checked for the presence of...

Страница 21: ...excessive number of connections terminals not made to original specification damage to seals incorrect fitting of glands etc Ensure that apparatus is mounted securely Ensure that seals or sealing mate...

Страница 22: ...s suitable for the refrigerant used Leak detection equipment shall be set at a percentage of the LFL of the refrigerant and shall be calibrated to the refrigerant employed and the appropriate percenta...

Страница 23: ...utlet for the vacuum pump is not close to any ignition sources and there is ventilation available 8 Charging procedures In addition to conventional charging procedures the following requirements shall...

Страница 24: ...ated on the scales before recovery takes place 7 Start the recovery machine and operate in accordance with manufacturer s instructions 8 Do not overfill cylinders No more than 80 volume liquid charge...

Страница 25: ...event of a refrigerant release Consult manufacturer if in doubt The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder and the relevant Waste Transfer...