JA95-N70 Audio Controller with RX Volume Controls - NVG
Installation and Operating Manual
Rev
C
Page 15
2.5.3.11
ICS Tie Line
The rated input and output levels of the intercom tie line can be selected as Type 1 or Type 2 (
Default Type 2
).
The quantity of external loads for a type1 intercom tie line can be selected from 0 to 3 (
Default 0
).
The quantity of external loads for a type 2 intercom tie line can be selected from 0 to 7 (
Default 0
).
2.5.3.12
Lighting Voltage Selection
The rated input level for the lighting voltage
may be selected from
+5 Vdc, +14 Vdc or +28Vdc
(
D28 Vdc
).
2.5.3.13
VOX
When the PAX Drop Cord Enable check box is checked, the VOX circuits for the passenger microphones are
configured for use with drop cords (
Default not checked
)
2.5.3.14
Connector Maps
This section contains connector maps and interconnects that are automatically generated to show changes that affect
the installation of the JA95-N70, such as switch labels and voltages. See
The VOX OFF Delay Time can be adjusted
from 0.50 to 2.00 sec (
Default 1 sec
).