JA95-091 Audio Controller - Dual ICS Input
Installation and Operating Manual
Rev A
Page 14
2.5.3.7
Alerts
Warning
: The internal audio alerts are intended only to supplement,
not
replace, airframe alerts such as ‘low
rotor RPM’, ‘engine out’ or ‘decision height alerting’. The alert audio feature is intended for use as a
secondary alerting system where another device provides the primary annunciation.
Audio Files
The JA95-091 has standard audio signals for each of the three alerts, and the audio files window allows these
signals to be customized with other recordings during the configuration process.
The default Alert signals loaded into the unit at the factory are:
JA95-091 Wav File (Sine 300Hz 10 sec) Rev A.WAV
JA95-091 Wav File (Sine 1000Hz 10 sec) Rev A.WAV
JA95-091 Wav File (Sine 3000Hz 10 sec) Rev A.WAV
Saving new Audio Files
If a new audio file is selected, it may be played using the arrow
to the right of the Message line.
It may be uploaded to the JA95-091 using the 'Program' menu
and selecting 'Program JA95-091 Messages…'.
Note that this pane will have different content if a JA95-091 is
not connected.
The levels of the three Alert Audio signals are individually adjustable
from 0 to -40 dB of the rated phone level.(
Default -12 dB
)