f) Plug in any remaining headsets, and check for correct ICS operation. Note that an incorrect cordset (drop cord)
or improper jack wiring may cause a wide range of problems, from loss of audio to a tone heard in the headset.
g) Check that all configurations settings are correct.
When all performance checks are satisfied, complete the necessary regulatory documentation before releasing the
aircraft for service. Refer to
2.5
Adjustments and Configuration using ProCS™
All the JA95-091 internal adjustments are set from the
Product Configuration Software ProCS™
. Configuration data is
sent to the JA95-091 via the front panel connector (
♫
/io), using the Configuration Cables and a computer running the
ProCS™ software. For configuration requirements, see section 2.5.1.
For full information on the configuration process, and for installation of ProCS™ on your computer, refer to the
on the Jupiter Avionics website -
www.jupiteravionics.com/productsoftware.
2.5.1
Configuration Cabling Requirements
To configure the JA95-091, it is necessary to load the
Product Configuration Software ProCS™
onto a Windows-
based computer as described in the
The cables required to configure the JA95-091 are not included with the unit.
Quantity
Description
JAC Part #
1
USB A to RS232 9-Pin Cable
CAB-USB-0002
1
Configuration Cable
JA99-001
2.5.2
ProCS™ Setup
The ProCS™ JA95-091 menu item 'ProCS Setup' provides a Setup drawing showing the cabling arrangement
for connecting the JA95-091 to a computer running the ProCS™.
2.5.3
Configurable Settings
A standard unit is shipped from the factory with all internal adjustments configured to the default levels. At installation,
it may be desirable to change some of these settings to suit the local operating environment.
Note
: To configure the JA95-091, power must be applied to the unit, and the mode (EMER/NORM) switch
must be in the NORM position
Within ProCS™, the configurable settings are grouped together into the following sections: