6
6
PT: Overheat protection indicator, when the
temperature is greater than 80 °C, the PT light
is on to indicate overheat protection.
CV: Constant voltage indicator, CV indicator light
indicates constant voltage output.
CC: Constant current indicator, CC indicator light
indicates constant current output.
COM: Communication indicator, when there is an
instruction input, the COM light will be on, indicating
communicating.
First, the use of voltage and current adjustment and
shutdown output instructions
Connect the input and output correctly to ensure that the input voltage is
within the required range. Reverse connection is strictly prohibited. The input
voltage must be higher than the output voltage by more than 0.5V.
Note: Input voltage range: 10V~75V;
Output current range: 0~16A (DPM-8616), 0~24A (DPM-8624);
Output voltage range: 0~60V.
2. Set the required voltage and current values. It should be noted that the
“V ”digital tube displays the voltage, the “A ”digital tube displays the current,
the decimal point of the voltage display value is in the second position (such
as 00.00), and the decimal point of the current display value is in the first
position (such as 0.000). After the setting is completed, press OK to turn on
the output. At this time, the CV or CC light is on to indicate that the output
state is turned on. The method of setting the voltage and current value is as
Содержание DPM-8605