Quickly load: Press M1, M2, M3, M4 to quickly load the data in M1, M2,

M3, M4 storage locations.

四、

Key lock: Press and hold the SET button to lock the button. When you

press and hold the SET button again, the button can be unlocked. After the
button is locked, the button lock on the display will turn into a red lock state,
indicating that the button is locked.

The key lock display interface is as follows:

.Upper and lower limit setting: After setting the voltage and current, select

the upper or lower limit in the function and save it, you can set the current
voltage and current value as the upper limit or lower limit. The upper limit is
displayed as MAX and the lower limit is displayed as MIN. If the upper and
lower limits are the same value, the display is LOCK. To cancel the limit,
select the limit reset function.

Press the SET button
and the cursor will
appear in the function
box position.

Press the OK button to

enter the function

adjustment and change

the parameters with the

left and right buttons or

knob.

Key lock status

Содержание DPM-8605

Страница 1: ...Check that the contents of the box are complete The contents of the box are as follows If the content does not match or the instrument is damaged please contact your dealer or the company Host DPM8600 programmable high power power supply 1 Accessories User Manual 1 Optional Programmable power wireless remote control 1 5V USB transfer cable 1 User Manual 1 3 Check the whole machine If the instrumen...

Страница 2: ...pped with wireless remote control The wireless controller adopts 2 4 inch LCD screen It has rich display content simple operation built in lithium battery can be recharged and it can control the switching power supply within 10 meters wirelessly A wireless controller can control multiple switching power supplies simultaneously Modular power supply is applied in several aspects 1 power mainly integ...

Страница 3: ...the DPM8624 as an example The DPM8608 operates in the same way as the DPM8624 The difference is in the current display The DPM8608 and DPM8605 currents display three decimal places such as 3 000 and the DPM8624 and DPM8616 currents display two decimal places such as 03 00 ...

Страница 4: ...8616 DPM8624 Label Description Label Description Power Switch Working status indicator Negative Input Positive Output Positive Input Negative Output LED digital tube Communication Interface Fan Function button Table 2 2 DPM8600 series digital power supply module description ...

Страница 5: ...5 5 Table 2 2 Display description of DPM8600 series power supply ...

Страница 6: ...e required range Reverse connection is strictly prohibited The input voltage must be higher than the output voltage by more than 0 5V Note Input voltage range 10V 75V Output current range 0 16A DPM 8616 0 24A DPM 8624 Output voltage range 0 60V 2 Set the required voltage and current values It should be noted that the V digital tube displays the voltage the A digital tube displays the current the d...

Страница 7: ...s 5V 3A Short press a certain value flashes Short press many times the flashing bit will move at different bits of voltage and current The value can be change the value by pressing and for example adjust 12V 5A press button to exit the adjustment state Press to turn the output on and off as the load current is less than the set current the output is constant voltage output and the CV light is on A...

Страница 8: ... settings of M9 or press to enter next interface Press to retum main interface or press to calibrate the display data For details of the calibration please see the function description below Press or to exit the temperature display interface Press button to save to M0 or press to enter next interface Press button to save to M9 or Press to enter next interface Press or to adjust to M3 press OK to s...

Страница 9: ...of the instrument which can control the fan speed and over temperature protection When the temperature is greater than 40 C the fan starts working and the fan speed increases by 1 level for every 5 C increase When the temperature reaches 60 C the fan rotates at maximum wind speed when the temperature is greater than 80 C the product over temperature protection automatically turns off the output SE...

Страница 10: ...ng is successful Short press to enter the fast response interface and the sub option is changed by pressing and 0 means slow 1 means fast then press OK the setting is successful Short press to enter the communication protocol selection interface and the sub option is changed by pressing and 0 means simple communication protocol 1 means MODBUS RTU communication protocol then press OK button the set...

Страница 11: ... our custom communication protocol it is easy to understand MODBUS communication protocol is the standard MODBUS communication protocol Quick response function introduction After the quick response is turned on the response time is short when the voltage is adjusted from high to low For example when the output is 30V adjust it directly to the output of 5V When the quick response is not turned on i...

Страница 12: ...rs remote control The wireless controller has a built in 3 7V 2000mA lithium battery that can be recharged It can be used for more than 10 hours at full power The wireless controller adopts a 2 4 inch TFT liquid crystal display with rich display content With multi function buttons and knobs it can be quickly set and adjusted and the operation is simple and fast ...

Страница 13: ...13 13 ...

Страница 14: ...18 Constant voltage indicator Operating Instructions 一 Voltage and current setting and on off output Press button V the cursor appears at the voltage setting rotate the knob to change the value and the left and right buttons can change the step value Press button A the cursor appears at the current setting the knob can be rotated to change the value and the left and right buttons can change the st...

Страница 15: ...nction settings press OK to enter its function settings press left or right button or rotate knob to change parameters then press OK the setting is successful Examples of the function setting display interface are as follows Boot default connection status Voltage setting state Current setting state When the constant voltage output is 5V 1A and the load current is less than the set current the outp...

Страница 16: ...d lower limit setting After setting the voltage and current select the upper or lower limit in the function and save it you can set the current voltage and current value as the upper limit or lower limit The upper limit is displayed as MAX and the lower limit is displayed as MIN If the upper and lower limits are the same value the display is LOCK To cancel the limit select the limit reset function...

Страница 17: ...sses different channels represent different host power supplies and which can perform one to many control display The host address is set to 00 meaning it is not controlled by any wireless controller 6 Quick response After the quick discharge is turned on the response time of the voltage from high to low is relatively short 7 Automatic output After the automatic output is turned on the output will...

Страница 18: ... lower limit is adjusted the setting area will display MAX indicating that the lower limit has been reached 10 Limit reset Cancel the upper and lower limit settings 11 Brightness The brightness adjustment range is from 1 to 100 12 Automatic shut down The time adjustment is up to 30 minutes the adjustment step value is 10 seconds and the setting is 0 seconds indicating constant light After the scre...

Отзывы: