9
1 - GENERAL INFORMATION
This canopy hood is designed to be fixed to any rigid vertical surface, over a gas or electric
hotplate and can be used either in the extraction mode (ducted to the outside) or in the
recirculation mode (internal recycling).
Before commencing the installation, consideration
should be given to the difficulties to be found during installation and to the bulky weight of
the hood. The installation work must be undertaken by a qualified and competent person
in conformity to the rules concerning the evacuation of contaminated air. The
manufacturer disclaims all liability for any damage or injury caused as a result of not
following the instructions for installation contained in the following text.
2 - COMPONENTS
The cooker hood is made up of (
fig. 1
):
2.1 - 1 canopy
C
complete with light controls and ventilating unit
2.2 - 1 telescopic chimney stack made up of:
1 upper stack
S
1 lower stack
I
2.3 - 1 reduction flange 150-120 Ø
A
2.4 - 1 stack fitting
R
2.5 - 1 directional grill
G
2.6 - 1 bag containing:
1 bracket
I
for fixing the hood unit, screws, rawl plugs and documents
2.7 - 1 backing
B
(optional)
3 - SAFETY WARNINGS
3.1- When used in the extraction mode the cooker hood ducting must not be connected to a
central heating flue, radiator or a water heater.
3.2- Before connection to the mains supply ensure that the mains voltage corresponds withthe
voltage on the rating plate inside the hood.
3.3- Connect the hood to the mains supply via a double pole switch which has 3 mm
clearance between the contacts. When using a plug to connect the hood to the power
supply, ensure that the plug used complies with national safety regulations and that it is
connected in an easily accessible position.
3.4- Ensure that the electric plant allows the hood to be correctly earthed.
3.5- When installed, the hood must be positioned at least 65 cm above a cooking appliance.
3.6- Never do flambé cooking under this cooker hood.
3.7- Never leave frying pans unattended during use as overheated fats and oils may catch fire.
3.8- Before carrying out any kind of maintenance or cleaning, disconnect the hood from the
mains supply.
3.9- If the room where the cooker hood is to be used contains other non-electric appliances
(such as gas appliances) ensure that there is an adequate supply of air to the room. When
the coooker hood is used in conjunction with other appliances supplied with energy other
than electricity, the negative pressure in the room must not exceed 0,04 mbar to prevent
fumes been drawn back into the room by the cooker hood.
Part 1 - INSTALLATION INSTRUCTIONS