Heating controls
6 720 645 817
(2010/09)
53
8.3
Weather-compensated controllers
FW 100
Application
•
Weather-compensated flow temperature controller
•
Constant output control
•
Communication with the heat source via 2-wire BUS
Function
•
2-wire BUS technology, reverse polarity protected connection
•
Controls one mixed or unmixed heating circuit
•
DHW program for DHW cylinder (adjustable time and temperature)
•
Solar DHW heating (with ISM 1)
•
Solar-optimised heating circuit and DHW heating as options
•
Optional FB 10 or FB 100 remote controls
•
7-day program with six switching times per day for one mixed or one unmixed heating
circuit and DHW heating
•
Date and time, automatic summer/winter changeover
•
Fault codes displayed in plain text
•
Switching modules IPM 1, ISM 1 (for mixed heating circuit, solar DHW heating)
•
Preinstalled programs adjustable to customer's requirements
•
Holiday function with date entry
•
Intuitive menu prompts with plain text support
•
Thermal disinfection possible
•
DHW circulation pump program
•
Screed drying program
•
Room temperature hook-up
•
Optimised heating curves
•
Adjustable heat-up speed (slow, normal, fast)
•
Info function
•
Remote management via Netcom 100
Installation
•
Wall mounting (height/width/depth: 119/134/45 mm)
•
Power supply 15 V via 2-wire BUS
Accessories
•
IPM 1 load switching module
•
ISM 1 solar module
•
FB 10 remote control
•
FB 100 remote control with plain text display
Part no. 7 719 002 923
Tab. 28