Junkers miniMAXX WR 11-2 B Series Скачать руководство пользователя страница 4

Information about the heater

? ??? ??? ???

 

(YYYY/MM)

4

2

Information about the heater

2.1

Category, type and approval no.

2.2

Technical identification code

W

Water gas heater

R

Proportional power adjustment

11

Capacity (l/min)

-2

Version 2

B

Electronic ignition powered by 1.5 V batteries

23

Appliance adjusted for natural gas

31

Appliance adjusted for GPL

S...

Country code

2.3

Package contents

Gas heater

Attachment elements

Connection elements

Heater documentation

Two 1.5 V batteries type R

Rubber holders (LPG heaters)

2.4

Description of the heater

Operating convenience, as the heater is ready to operate 
by simply pressing a switch.

Heater for wall-mounting

Ignition by electronic device triggered when the water 
valve opens

Great savings in comparison with conventional heat-
ers, due to the possibility of power adjustment and no 
permanent pilot flame

Natural gas/LPG burner

Semi-permanent pilot burner which only functions 
during the period between the opening of the water 
valve and the ignition of the main burner

Combustion chamber without tin/lead covering

Water valve in fibreglass-reinforced polyamide, 100% 
recyclable

Automatic adjustment of the water flow by means of 
a device which permits a constant flow to be main-
tained in spite of variable pressure supplies

Gas flow adjustment proportional to the water flow to 
maintain a constant high temperature.

Safety devices: 

Ionisation probe to check for accidental extinction 
of the burner flame

Flue gas safety device which turns off the heater in 
case of inadequate combusted gas evacuation con-
ditions

Temperature limiter which prevents overheating of 
the combustion chamber

2.5

Special accessories

Conversion kit from natural gas to butane/propane 
and vice-versa

Model

WR 11/14/18 -2 B...

Category

II

2H3+

Type

B

11BS

Tab. 1

W

R

11

-2

B

23
31

S...

W

R

14

-2

B

23
31

S...

W

R

18

-2

B

23
31

S...

Tab. 2

0464

Содержание miniMAXX WR 11-2 B Series

Страница 1: ...g this unit in operation Observe the warnings in the manuals The installation room must fulfill the ventilation requirements Installation by an authorised person only Installation Manual and Operating...

Страница 2: ...4 1 Important information 10 4 2 Selection of the place of installation 10 4 3 Heater mounting 11 4 4 Water connection 11 4 5 Gas connection 11 4 6 Startup 11 5 Operating instructions 12 5 1 Batteries...

Страница 3: ...bstances for example halogenated hydrocarbons containing chlorine and fluoride composites Client information B Inform the client about the function and operation of the appliance B This appliance is n...

Страница 4: ...ermanent pilot flame Natural gas LPG burner Semi permanent pilot burner which only functions during the period between the opening of the water valve and the ignition of the main burner Combustion cha...

Страница 5: ...tor 34 LED Burner status check 35 Switch LED Battery status check 36 Front 37 Opening for mounting on the wall 38 Connection collar to the combustion gases pipe 39 Flue with non return device 40 Gas v...

Страница 6: ...ressure 8 Slow ignition valve 9 Venturi 10 Temperature volume selector 11 Water valve 12 Command cone 13 Water flow regulator 14 Water filter 15 Micro switch 16 Cold water pipe 17 Diaphragm 18 Main ga...

Страница 7: ...so just turn on the switch Fig 8 After this procedure automatic ignition occurs when ever a hot water tap is opened First the pilot burner is lit and approximately four seconds afterwards the main bur...

Страница 8: ...imum permissible pressure pw bar 12 12 12 Temperature selector in fully clockwise position Temperature rise C 50 50 50 Flow range l min 2 5 5 2 7 2 8 8 Minimum operating pressure pwmin bar 0 1 0 1 0 2...

Страница 9: ...tions YYYY MM 9 3 Regulations Any local by laws and regulations pertaining to installa tion and use of gas heated appliances must be observed Please refer to the laws that should be attended in your c...

Страница 10: ...ated hydrocarbons con tained in solvents paints glues engine gases and var ious domestic detergents If necessary take adequate measures Respect the minimum installation clearances indi cated in Fig 4...

Страница 11: ...ause a blockage B Identify the cold water pipe Fig 5 item A and the hot water pipe Fig 5 item B so as to avoid any pos sible mis connection B Connect the water pipes to the water valve using the provi...

Страница 12: ...eater B Check if the gas indicated on the rating plate is the same as the one used at the location B Open the gas valve B Open the water valve 5 3 Turning the heater on and off Turning on B Press the...

Страница 13: ...ter temperature Regulating the temperature to the minimum required value reduces energy consumption as well as the possi bility of limescale deposits in the combustion chamber 5 6 Purge the appliance...

Страница 14: ...ting screw B Open various hot water taps B Using the adjusting screw regulate the pressure until obtaining the values indicated in the table 6 B Seal the adjusting screw once again Minimum gas flow ad...

Страница 15: ...an it carefully Water filter B Replace the water filter installed in the inlet of the water valve Pilot and main burner B Remove and clean pilot burner B Remove and clean pilot injector 7 2 Startup af...

Страница 16: ...bout 50 cm long with sealed end B Fit pipe vertically B Start up appliance at rated output and set tempera ture control to maximum temperature Under those conditions the appliance should shut down aft...

Страница 17: ...adjust it according to the desired water temperature Water is not heated no flame Insufficient gas supply Check the reducer and replace it if inadequate or malfunctioning Check if the bottles butane...

Страница 18: ...possible tech nology and materials under economic considerations to protect the environment Packaging We participate in the recycling program of the respective country to ensure optimal recycling All...

Страница 19: ...YYYY MM 19...

Страница 20: ......

Отзывы: