Maintenance

? ??? ??? ???

 

(YYYY/MM)

15

7

Maintenance

To ensure that gas consumption and the environmental 
load (pollution, etc.) remain as negligible as possible 
over a longer period of time, we recommend that you 
assure to have the appliance maintained on an annual 
basis (inspection) or if necessary (maintenance).
These jobs can only be done by a Junkers Technical 
Assistance delegate.

B

Use only authentic spare parts and accessories.

B

Order the spare parts according to the spare parts 
catalogue for the heater.

B

Substitute dismantled joints and o-rings with new 
ones.

B

Only the following lubricants must be used:

On hydraulic parts: Unisilikon L 641 (8 709 918 
413)

Threaded joints: HFt 1 v 5 (8 709 918 010).

7.1

Periodic maintenance tasks

Functional checks

B

Ensure that all safety, regulatory and checking 
elements are in good working order.

Heat exchanger

B

Inspect the heat exchanger.

B

If it is dirty:

Dismantle the chamber and remove the regulator.

Clean the chamber with a pressurized water jet.

B

If the dirt resists: soak soiled parts in hot water with 
detergent and clean carefully.

B

If necessary: de-scale the interior of the heat 
exchanger and connection tubes.

B

Reassemble the heat exchanger using new joints.

B

Remount the regulator on its support.

Burner 

B

Inspect the burner annually and clean as necessary.

B

If it is very dirty (grease, soot): Dismantle the burner 
and soak it in hot water with detergent and clean it 
carefully.

Water filter

B

Replace the water filter installed in the inlet of the 
water valve.

Pilot and main burner

B

Remove and clean pilot burner.

B

Remove and clean pilot injector.

7.2

Startup after maintenance work

B

Re-open all connections. Ensure there are no gas 
leaks.

B

Read chapter 5 “Use” and chapter 6 “Adjustments”.

7.3

Flue gas safety device

Operation and precautions

The flue gas safety device checks the effectiveness of 
flue gas extraction by the flue. If it is inadequate, the 
appliance switches off automatically so that the combus-
tion fumes do not escape into the room in which the 
appliance has been installed. The flue gas safety device 
resets after a cooling-down period.

If the appliance shuts down while in operation:

B

Ventilate the room.

B

10 minutes later, turn on the heater once again.
Call a qualified technician if the same thing happens 
again.

Maintenance*

If faults occur on the flue gas safety device, proceed as 
follows:

B

Undo flue gas safety device fixing screw.

B

Loosen temperature limiters connectors.

B

Replace damaged component with new one and refit 
using the reverse of the procedure set out in the table 
above.

Maintenance must only be performed by a 
qualified technician.

Warning: 

Before performing any maintenance work:

B

Close the water flow valve.

B

Close the gas flow valve.

Warning: 

Is forbidden to start up the appliance 
without water filter correctly assembled.

Danger: 

The flue gas safety device must not under 
any circumstances be switched off, simu-
lated or replaced by any other component

Danger: 

The user must never make any modifica-
tions to the appliance.

Содержание miniMAXX WR 11-2 B Series

Страница 1: ...g this unit in operation Observe the warnings in the manuals The installation room must fulfill the ventilation requirements Installation by an authorised person only Installation Manual and Operating...

Страница 2: ...4 1 Important information 10 4 2 Selection of the place of installation 10 4 3 Heater mounting 11 4 4 Water connection 11 4 5 Gas connection 11 4 6 Startup 11 5 Operating instructions 12 5 1 Batteries...

Страница 3: ...bstances for example halogenated hydrocarbons containing chlorine and fluoride composites Client information B Inform the client about the function and operation of the appliance B This appliance is n...

Страница 4: ...ermanent pilot flame Natural gas LPG burner Semi permanent pilot burner which only functions during the period between the opening of the water valve and the ignition of the main burner Combustion cha...

Страница 5: ...tor 34 LED Burner status check 35 Switch LED Battery status check 36 Front 37 Opening for mounting on the wall 38 Connection collar to the combustion gases pipe 39 Flue with non return device 40 Gas v...

Страница 6: ...ressure 8 Slow ignition valve 9 Venturi 10 Temperature volume selector 11 Water valve 12 Command cone 13 Water flow regulator 14 Water filter 15 Micro switch 16 Cold water pipe 17 Diaphragm 18 Main ga...

Страница 7: ...so just turn on the switch Fig 8 After this procedure automatic ignition occurs when ever a hot water tap is opened First the pilot burner is lit and approximately four seconds afterwards the main bur...

Страница 8: ...imum permissible pressure pw bar 12 12 12 Temperature selector in fully clockwise position Temperature rise C 50 50 50 Flow range l min 2 5 5 2 7 2 8 8 Minimum operating pressure pwmin bar 0 1 0 1 0 2...

Страница 9: ...tions YYYY MM 9 3 Regulations Any local by laws and regulations pertaining to installa tion and use of gas heated appliances must be observed Please refer to the laws that should be attended in your c...

Страница 10: ...ated hydrocarbons con tained in solvents paints glues engine gases and var ious domestic detergents If necessary take adequate measures Respect the minimum installation clearances indi cated in Fig 4...

Страница 11: ...ause a blockage B Identify the cold water pipe Fig 5 item A and the hot water pipe Fig 5 item B so as to avoid any pos sible mis connection B Connect the water pipes to the water valve using the provi...

Страница 12: ...eater B Check if the gas indicated on the rating plate is the same as the one used at the location B Open the gas valve B Open the water valve 5 3 Turning the heater on and off Turning on B Press the...

Страница 13: ...ter temperature Regulating the temperature to the minimum required value reduces energy consumption as well as the possi bility of limescale deposits in the combustion chamber 5 6 Purge the appliance...

Страница 14: ...ting screw B Open various hot water taps B Using the adjusting screw regulate the pressure until obtaining the values indicated in the table 6 B Seal the adjusting screw once again Minimum gas flow ad...

Страница 15: ...an it carefully Water filter B Replace the water filter installed in the inlet of the water valve Pilot and main burner B Remove and clean pilot burner B Remove and clean pilot injector 7 2 Startup af...

Страница 16: ...bout 50 cm long with sealed end B Fit pipe vertically B Start up appliance at rated output and set tempera ture control to maximum temperature Under those conditions the appliance should shut down aft...

Страница 17: ...adjust it according to the desired water temperature Water is not heated no flame Insufficient gas supply Check the reducer and replace it if inadequate or malfunctioning Check if the bottles butane...

Страница 18: ...possible tech nology and materials under economic considerations to protect the environment Packaging We participate in the recycling program of the respective country to ensure optimal recycling All...