Problems

? ??? ??? ???

 

(YYYY/MM)

17

8

Problems

8.1

Problem/cause/solution

Assembly, maintenance and repairs must be performed by qualified technicians only. The following chart offers solu-
tions to possible problems (solutions followed by an * must be undertaken by qualified technicians only).

Problem

Cause

Solution

The heater does not ignite.
  

Slow and difficult ignition of the 
burner. 

LED next to the switch flashes.

Batteries flat or not inserted cor-
rectly, or switch turned off.
 
Flat batteries.

Check position and replace them.
  

Replace them.

Water at low temperature.

Check the temperature selector 
position and adjust it according to 
the desired water temperature.

Water is not heated, no flame.

Insufficient gas supply.

Check the reducer and replace it if 
inadequate or malfunctioning.
 
Check if the bottles (butane) 
freeze during operation, and if so, 
move them to a warmer place.

The burner turns off the heater is 
operating.

Temperature limiter has tripped.
  
  

Flue gas safety device has tripped.

Wait 10 minutes and restart the 
heater. If the problem persists, call 
a qualified technician.
 
Vent the area. Wait 10 minutes and 
restart the heater. If the problem 
persists, call a qualified techni-
cian.

Reduced water flow.

Insufficient water supply pressure.
 
Dirty taps or mixers.
 
Water valve blocked.
 
Combustion chamber blocked 
(limescale).

Check and correct. *
  
Check and clean.
  
Clean filter.* 

Clean and de-lime if necessary.*

Tab. 7

Содержание miniMAXX WR 11-2 B Series

Страница 1: ...g this unit in operation Observe the warnings in the manuals The installation room must fulfill the ventilation requirements Installation by an authorised person only Installation Manual and Operating...

Страница 2: ...4 1 Important information 10 4 2 Selection of the place of installation 10 4 3 Heater mounting 11 4 4 Water connection 11 4 5 Gas connection 11 4 6 Startup 11 5 Operating instructions 12 5 1 Batteries...

Страница 3: ...bstances for example halogenated hydrocarbons containing chlorine and fluoride composites Client information B Inform the client about the function and operation of the appliance B This appliance is n...

Страница 4: ...ermanent pilot flame Natural gas LPG burner Semi permanent pilot burner which only functions during the period between the opening of the water valve and the ignition of the main burner Combustion cha...

Страница 5: ...tor 34 LED Burner status check 35 Switch LED Battery status check 36 Front 37 Opening for mounting on the wall 38 Connection collar to the combustion gases pipe 39 Flue with non return device 40 Gas v...

Страница 6: ...ressure 8 Slow ignition valve 9 Venturi 10 Temperature volume selector 11 Water valve 12 Command cone 13 Water flow regulator 14 Water filter 15 Micro switch 16 Cold water pipe 17 Diaphragm 18 Main ga...

Страница 7: ...so just turn on the switch Fig 8 After this procedure automatic ignition occurs when ever a hot water tap is opened First the pilot burner is lit and approximately four seconds afterwards the main bur...

Страница 8: ...imum permissible pressure pw bar 12 12 12 Temperature selector in fully clockwise position Temperature rise C 50 50 50 Flow range l min 2 5 5 2 7 2 8 8 Minimum operating pressure pwmin bar 0 1 0 1 0 2...

Страница 9: ...tions YYYY MM 9 3 Regulations Any local by laws and regulations pertaining to installa tion and use of gas heated appliances must be observed Please refer to the laws that should be attended in your c...

Страница 10: ...ated hydrocarbons con tained in solvents paints glues engine gases and var ious domestic detergents If necessary take adequate measures Respect the minimum installation clearances indi cated in Fig 4...

Страница 11: ...ause a blockage B Identify the cold water pipe Fig 5 item A and the hot water pipe Fig 5 item B so as to avoid any pos sible mis connection B Connect the water pipes to the water valve using the provi...

Страница 12: ...eater B Check if the gas indicated on the rating plate is the same as the one used at the location B Open the gas valve B Open the water valve 5 3 Turning the heater on and off Turning on B Press the...

Страница 13: ...ter temperature Regulating the temperature to the minimum required value reduces energy consumption as well as the possi bility of limescale deposits in the combustion chamber 5 6 Purge the appliance...

Страница 14: ...ting screw B Open various hot water taps B Using the adjusting screw regulate the pressure until obtaining the values indicated in the table 6 B Seal the adjusting screw once again Minimum gas flow ad...

Страница 15: ...an it carefully Water filter B Replace the water filter installed in the inlet of the water valve Pilot and main burner B Remove and clean pilot burner B Remove and clean pilot injector 7 2 Startup af...

Страница 16: ...bout 50 cm long with sealed end B Fit pipe vertically B Start up appliance at rated output and set tempera ture control to maximum temperature Under those conditions the appliance should shut down aft...

Страница 17: ...adjust it according to the desired water temperature Water is not heated no flame Insufficient gas supply Check the reducer and replace it if inadequate or malfunctioning Check if the bottles butane...

Страница 18: ...possible tech nology and materials under economic considerations to protect the environment Packaging We participate in the recycling program of the respective country to ensure optimal recycling All...

Страница 19: ...YYYY MM 19...

Страница 20: ......

Отзывы: