2.13 Specifications
2.14 Product Data on Energy Consumption
1) See Chapter 2.15.1 "Coding plug numbers for heaters", page 10.
6720813052 (2016/10)
Cerapur GC9000iW
8,8
In
48,9
52
Maximum flow temperature
mbar
98,1
80
Emission values according to EN 13384
230/50 Hz
31
40
electric power consumption
CO2/O2 content, full load, propane
Connection condensate
1,51
103,6
10,2 / 5,5 10,2 / 5,5 10,2 / 5,5 10,2 / 5,5 10,2 / 5,5 10,2 / 5,5
155
kW
customs service
na
4,5 - 8,5
20 H 23
50
hot water
29,2
%
Exhaust gas temperature 40/30 °C, partial load
50 (42,5 - 57,5)
5,1
l/h
g/s
50 H 23
Device dimensions and weight
kW
148
10
19,3
30,2
supply voltage, frequency
- -
Ø 30
maximum operating pressure device
30,2
%
98,1
10,8 / 4,6 10,8 / 4,6 10,8 / 4,6 10,8 / 4,6 10,8 / 4,6 10,8 / 4,6
connection gas
1,37
82
48
9,5 / 4,0
8,6 / 5,5
2
150
21,6
52
na
l/h
48
2,7
°C
5
na
102,5
97,4
156
Nominal connection pressure for propane
3
60
kg
mbar
3
electrical data
¾ union nut
Exhaust gas temperature 40/30 °C, full load
20 (18 - 25)
40 H 23
Exhaust gas value group for LAS Ø
exhaust system, room air-dependent Ø
exhaust system, room air-independent
1,37
2,7
59 (801)) 59
(1401))
1
- -
kW
2
°C
42
13,4
17,1
Max. amount of condensate (TR = 30 °C) pH
value approx.
na
98
56 124
CO2/O2 content, part load, propane free
fan discharge, standard exhaust systems free fan discharge, long exhaust
systems 60/100
44
Nominal connection pressure for natural gas LL (range)
40,8
49,9
124
kW
- -
bar
mm
mm
103,6
Exhaust mass flow at full load
Maximum connection pressure hot water
31
Well
1,37
59 (1401))
Unit 20 E 23
%
18,6
98
8,6 / 5,5 8,6 / 5,5 8,6 / 5,5 8,6 / 5,5
Connection heating water
1,37
19,3
148
4
47
220
na
3,1
Cerapur GC9000iW
71
water content
56
47,9
31
Residual head at ÿT = 20K
735 × 520 × 425
3
maximum amount of condensate for natural gas LL/E, 40/30 °C
30,2
41
setting values
CO2/O2 content, part load, natural gas LL/E
60
5
Resistance at ÿT = 20K
pipe connections
19,3
9,5 / 4,0 9,5 / 4,0 9,5 / 4,0 9,5 / 4,0
30,2
°C
31
mbar
Min. heat load for natural gas LL/E Max. heat load
for natural gas LL/E Nominal heat output (Pn) 80/60
°C for natural gas LL/E Nominal heat output (Pn) 50/30 °C for
natural gas LL/E Maximum hot water output for natural gas LL /E
Maximum output boiler efficiency (Pn max) - 80/60 °C Maximum
output boiler efficiency (Pn max) - 50/30 °C heating circuit
l
Condensate
9,5 / 4,0
3,1
na
40,8
IN
2
6,3
height × width × depth
69
60
%
G61, with gas type conversion set G62 (overpressure)
G1½
CO2/O2 content, full load, natural gas LL/E
electrical protection class
29,2
G 1
- -
20
30 and 23
mm
Exhaust gas temperature 80/60 °C, full load
102,6
20 (17 - 25)
19,3
Well
1,37
kW
8,6 / 5,5
°C
220
2
30
3
°C
450
Maximum hot water temperature
13,4
44
mbar
102
bar
weight
31
102,6
18,6
142
59 (801))
bar
customs service
80/125 concentric
%
30
30 H 23
Minimum connection pressure hot water
20
%
3
mm
mbar
69
130
300
4,1
74
exhaust connection
Nominal connection pressure for natural gas E (range)
97
48,9
78
31
8,8
The product data on energy consumption can be found in the user manual for the operator.
Product Information | 9
2.13.1 Device Data
Tab. 4 Technical data
IP X4D (X0D; B23; B33)
Machine Translated by Google
Содержание Cerapur 9000i
Страница 41: ...6720813052 2016 10 Cerapur GC9000iW 41 notes Machine Translated by Google...
Страница 42: ...6720813052 2016 10 Cerapur GC9000iW 42 notes Machine Translated by Google...
Страница 43: ...Cerapur GC9000iW 6720813052 2016 10 43 notes Machine Translated by Google...
Страница 45: ...Machine Translated by Google...