
If a power supply is not functioning normally, perform the following tasks to diagnose and correct the
problem:
•
If a red-alarm condition occurs, use the show chassis alarms command to determine the source of the
problem.
NOTE:
If the system temperature exceeds the red-alarm threshold, Junos OS shuts down
all power supplies so that no status is displayed.
Junos OS also can shut down one of the power supplies for other reasons. In this case, the
remaining power supplies provide power to the services gateway, and you can still view the
system status through the CLI or J-Web interface.
NOTE:
The services gateway shuts down automatically if the device temperature exceeds
the red-alarm threshold.
•
Check that the AC input switch (—) or DC circuit breaker (|) is in the on position and that the power
supply is receiving power.
•
Verify that the source circuit breaker has the proper current rating. Each power supply must be connected
to a separate source circuit breaker.
•
Verify that the AC power cord or DC power cables from the power source to the services gateway are
not damaged. If the insulation is cracked or broken, immediately replace the cord or cable.
•
Connect the power supply to a different power source with a new power cord or power cables. If the
power supply status LEDs indicate that the power supply is not functioning normally, the power supply
is the source of the problem. Replace the power supply with a spare, as described in
SRX4600 Services Gateway AC Power Supply” on page 91
or
“Replacing an SRX4600 Services Gateway
.
•
Verify that power supply is functioning properly by checking the status of power supply LED. For more
information, see
“SRX4600 Power System” on page 35
•
If you cannot determine the cause of the problem or need additional assistance while troubleshooting
a services gateway, open a support case using the Case Manager link at:
https://www.juniper.net/support/
, or call 1-888-314-JTAC (within the United States) or 1-408-745-9500.
Using the RESET Button on the SRX4600 Services Gateway
To cold reboot the SRX4600 Services Gateway, press and hold the RESET button for less than 5 seconds.
134
Содержание SRX-4600
Страница 1: ...SRX4600 Services Gateway Hardware Guide Published 2020 02 28 ...
Страница 18: ......
Страница 42: ......
Страница 62: ......
Страница 82: ......
Страница 122: ...5 CHAPTER Troubleshooting Hardware Troubleshooting the SRX4600 127 ...
Страница 123: ......
Страница 134: ......
Страница 147: ...151 ...
Страница 150: ...Restricted Access Area Warning 154 ...
Страница 157: ...161 ...
Страница 170: ...Jewelry Removal Warning 174 ...
Страница 173: ...Operating Temperature Warning 177 ...
Страница 183: ...DC Power Disconnection Warning 187 ...
Страница 187: ...DC Power Wiring Sequence Warning 191 ...
Страница 190: ...DC Power Wiring Terminations Warning 194 ...
Страница 193: ...DC Power Disconnection Warning 197 ...
Страница 197: ...DC Power Wiring Sequence Warning 201 ...
Страница 200: ...DC Power Wiring Terminations Warning 204 ...