SCB LEDs—Two LEDs,
OK
and
FAIL
, indicate the status of each SCB. Green indicates
OK and red indicates a failure. The SCB LEDs are located on the left of the craft interface
along the bottom.
•
Fan LEDs—Two LEDs indicate the status of the fans. Green indicates the fans are
functioning normally and red indicates a fan has failed. The fan LEDs are located on
the upper left of the craft interface.
Component LEDs
The following LEDs are located on various router components and display the status of
those components:
•
DPC LED—One LED labeled
OK/FAIL
on each DPC faceplate indicates the DPC's status.
For more information, see the
MX Series Interface Module Reference
•
FPC LED—One LED labeled
OK/FAIL
on each FPC faceplate indicates the FPC's status.
•
MPC LED—One LED labeled
OK/FAIL
on each FPC faceplate indicates the FPC's status.
•
MIC LED—One LED labeled
OK/FAIL
on each MIC faceplate indicates the MIC's status.
For more information, see the
MX Series Interface Module Reference
•
PIC LED—One LED labeled
OK/FAIL
on each PIC faceplate indicates the PIC's status.
For more information, see the
MX Series Interface Module Reference
•
SCB LEDs—Three LEDs, labeled
FABRIC ACTIVE
,
FABRIC ONLY
, and
OK/FAIL
, on each
SCB faceplate indicate the status of the SCB. If no LEDs are lit, the master RE might
still be booting or the SCB is not receiving power.
•
Routing Engine LEDs—Four LEDs, labeled
MASTER
,
HDD
,
ONLINE
, and
FAIL
on each
Routing Engine faceplate indicate the status of the Routing Engine and hard disk drive.
•
Power supply LEDs—Two LEDs on each power supply faceplate indicate the status of
that power supply.
Juniper Networks Technical Assistance Center
If you need assistance during troubleshooting, you can contact the Juniper Networks
Technical Assistance Center (JTAC) by using the Web or by telephone.
Troubleshooting the MX480 Cooling System
Problem
Description:
The fans in the fan tray are not functioning normally.
Solution
Follow these guidelines to troubleshoot the fans:
•
Check the fan LEDs and alarm LEDs on the craft interface.
•
If the red alarm LED on the craft interface lights, use the CLI to get information about
the source of an alarm condition:
user@host> show chassis alarms
.
If the CLI output lists only one fan failure, and the other fans are functioning normally,
the fan is most likely faulty and you must replace the fan tray.
355
Copyright © 2019, Juniper Networks, Inc.
Chapter 5: Troubleshooting Hardware
Содержание MX480
Страница 14: ...Copyright 2019 Juniper Networks Inc xiv MX480 Universal Routing Platform Hardware Guide...
Страница 22: ...Copyright 2019 Juniper Networks Inc xxii MX480 Universal Routing Platform Hardware Guide...
Страница 138: ...Copyright 2019 Juniper Networks Inc 138 MX480 Universal Routing Platform Hardware Guide...
Страница 168: ...Copyright 2019 Juniper Networks Inc 168 MX480 Universal Routing Platform Hardware Guide...
Страница 352: ...Copyright 2019 Juniper Networks Inc 352 MX480 Universal Routing Platform Hardware Guide...
Страница 382: ...Copyright 2019 Juniper Networks Inc 382 MX480 Universal Routing Platform Hardware Guide...
Страница 420: ...Copyright 2019 Juniper Networks Inc 420 MX480 Universal Routing Platform Hardware Guide...