Power requirements
•
Power consumption at different temperatures when all ports are configured in 10-
Gbps speed:
25° C: 420 W (without MACSec), 430 W (with MACSec)
40° C: 430 W (without MACSec), 450 W (with MACSec)
55° C: 450 W (without MACSec), 480 W (with MACSec)
•
Power consumption at different temperatures when all ports are configured in 1-
Gbps speed:
25° C: 360 W (without MACSec), 370 W (with MACSec)
40° C: 370 W (without MACSec), 390 W (with MACSec)
55° C: 390 W (without MACSec), 420 W (with MACSec)
LEDs
PWR LED
•
Steady green—Line-card power is ok.
•
Steady red—Line-card power-on has failed.
•
Off—Line card is not receiving power.
STS LED
•
Steady green (blinking green when the beacon or the port location is on)—Line card is
online.
•
Blinking green—The line card is booting.
•
Steady red (blinking red when the beacon or the port location is on)—Line card is
faulty or an alarm has been raised.
•
Off—Line card is disabled or offline.
Port LED
•
Off—Port does not have a transceiver module.
•
Steady green (blinking green when the beacon or the port location is on)—Port link is
up with no alarms or failures.
•
Steady amber (blinking amber when the beacon or the port location is on)—Port link
is down because the port is disabled through the CLI or the port encountered errors
such as loss of signal, local fault, or remote fault.
72