Figure 67: Removing the M120 Air Filter
Installing the M120 Air Filter
To install the front air filter (see Figure 68 on page 140):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect
the strap to one of the ESD points on the chassis.
2.
Insert the air filter element into the chassis by sliding it straight into the chassis until
it stops.
3.
While pushing the air filter straight back into the chassis, lift the front edge of the air
filter to secure it under the hooks.
4.
Reinstall the air filter faceplate onto the chassis, and fasten the captive screws on
both sides.
5.
Lower the cable management system back into position.
6.
Rearrange the PIC cables in the cable management system. For more information
about proper cable arrangement, see “Maintaining M120 PICs and PIC Cables” on
page 112.
139
Copyright © 2010, Juniper Networks, Inc.
Chapter 14: Replacing M120 Hardware Components
All manuals and user guides at all-guides.com