JSA5800 Site Guidelines and Requirements
IN THIS SECTION
General Site Installation Guidelines for the JSA5800 Appliance | 13
JSA5800 Appliance Physical Specifications | 14
JSA5800 Appliance Rack Requirements | 16
Additional Hardware Requirements | 17
General Site Installation Guidelines for the JSA5800 Appliance
The following precautions can help you plan an acceptable operating environment for your JSA5800
appliance and avoid environmentally caused equipment failures:
• For the cooling system to function properly, the airflow around the chassis must be unrestricted.
Allow sufficient clearance between the front and back of the chassis and adjacent equipment. Ensure
that there is adequate circulation in the installation location.
• Follow the electrostatic discharge (ESD) procedures to avoid damaging the equipment. Static
discharge can cause components to fail, either completely or intermittently over time.
NOTE: Install the appliance only in restricted areas, such as dedicated equipment rooms and
equipment closets, in accordance with Articles 110–16, 110–17, and 110–18 of the National
Electrical Code, ANSI/NFPA 70.
SEE ALSO
Additional Hardware Requirements | 0
JSA5800 Appliance Rack Requirements | 0
JSA5800 Appliance Physical Specifications | 0
13
Содержание JSA5800
Страница 1: ...Juniper Secure Analytics 5800 Hardware Guide Published 2021 06 03...
Страница 7: ...1 CHAPTER Overview JSA5800 System Overview 2 JSA5800 Chassis 4...
Страница 18: ...2 CHAPTER Site Planning Preparation and Specifications JSA5800 Site Guidelines and Requirements 13...
Страница 25: ...JSA5800 Chassis 4 JSA5800 Installation Overview 21 19...
Страница 47: ...4 CHAPTER Maintaining Components Maintaining the JSA5800 RAID Array 42 Maintaining JSA5800 Power System 42...
Страница 53: ...JSA5800 Chassis 4 47...
Страница 54: ...5 CHAPTER Troubleshooting Hardware Contacting Juniper Networks Technical Assistance Center 49...