Table 2: Text and Syntax Conventions (continued)

Examples

Description

Convention

Configure the machine’s domain

name:

[edit]

root@# set system domain-name

domain-name

Represents variables (options for

which you substitute a value) in

commands or configuration

statements.

Italic text like this

To configure a stub area, include

the stub statement at the [edit

protocols ospf area area-id]

hierarchy level.

The console port is labeled

CONSOLE.

Represents names of configuration

statements, commands, files, and

directories; configuration hierarchy

levels; or labels on routing platform

components.

Text like this

stub <default-metric metric>;

Encloses optional keywords or

variables.

< > (angle brackets)

broadcast | multicast

(string1 string2 string3)

Indicates a choice between the

mutually exclusive keywords or

variables on either side of the symbol.

The set of choices is often enclosed

in parentheses for clarity.

| (pipe symbol)

rsvp { # Required for dynamic MPLS

only

Indicates a comment specified on the

same line as the configuration

statement to which it applies.

# (pound sign)

community name members [

community-ids ]

Encloses a variable for which you can

substitute one or more values.

[ ] (square brackets)

[edit]

routing-options {

static {

route default {

nexthop address;

retain;

}

}

}

Identifies a level in the configuration

hierarchy.

Indention and braces ( { } )

Identifies a leaf statement at a

configuration hierarchy level.

; (semicolon)

GUI Conventions

ix

Содержание CTP151 Platform

Страница 1: ...Juniper Networks CTP151 Circuit to Packet Platform Hardware Guide Published 2020 02 07...

Страница 2: ...s the right to change modify transfer or otherwise revise this publication without notice Juniper Networks CTP151 Circuit to Packet Platform Hardware Guide Revision History February 2020 Revision 1 Th...

Страница 3: ...of CTP151 Platform 5 Chassis Status LEDs 5 CTP151 Cooling System 7 Power Supply in the CTP151 Device 8 CTP151 Interface Modules 9 CTP151 Serial Interface Module 9 CTP151 Multiservice Interface Module...

Страница 4: ...rt Adapter Pinout Information for a CTP151 Device 32 CTP151 Interface Module HD 26 Connector Cable Pinouts 33 EIA 530 Connector Interface Signal Pinouts DB 25 Female DCE 34 EIA 530 Connector Interface...

Страница 5: ...nterface Module Processor Module or Clock Module 61 Cabling 65 Connecting a CTP151 Device to a Network for Out of Band Management 65 Connecting a CTP151 Device to a Management Console 66 Connecting a...

Страница 6: ...Returning a CTP151 Device or Component for Repair or Replacement 89 Locating the Chassis Serial Number ID Label on a CTP151 Device 90 Contacting Customer Support to Obtain a Return Materials Authoriza...

Страница 7: ...at https www juniper net documentation If the information in the latest release notes differs from the information in the documentation follow the product Release Notes Juniper Networks Books publishe...

Страница 8: ...text and syntax conventions used in this guide Table 2 Text and Syntax Conventions Examples Description Convention To enter configuration mode type the configure command user host configure Represent...

Страница 9: ...b default metric metric Encloses optional keywords or variables angle brackets broadcast multicast string1 string2 string3 Indicates a choice between the mutually exclusive keywords or variables on ei...

Страница 10: ...stem Click TechLibrary Feedback on the lower right of any page on the Juniper Networks TechLibrary site and do one of the following Click the thumbs up icon if the information on the page was helpful...

Страница 11: ...niper net Find product documentation https www juniper net documentation Find solutions and answer questions using our Knowledge Base https kb juniper net Download the latest versions of software and...

Страница 12: ...1 PART Overview CTP151 Platform Overview 3 CTP151 Interface Modules 9...

Страница 13: ......

Страница 14: ...t chassis high port density and multiple Ethernet interfaces Each CTP Series platform runs the CTP operating system CTPOS and can be managed by the Juniper Networks CTPView Network Management System T...

Страница 15: ...front panel components of a CTP151 Figure 1 Front Panel Components of a CTP151 g100902 1 2 3 4 6 9 8 7 5 6 1 Interface module slots Mini USB console port 7 2 Two 1 Gigabit Ethernet 10 Gigabit Ethernet...

Страница 16: ...ounding points 4 Serial number RELATED DOCUMENTATION Introducing CTP Series Platforms 3 LED Details of CTP151 Platform 5 CTP151 Serial Interface Module 9 CTP151 T1 E1 Interface Module 12 LED Details o...

Страница 17: ...mode command show chassis led Table 3 Chassis Status LEDs in a CTP151 Description Color State LED Label The device is powered off or is halted Off SYS System The device is running but the ctpd proces...

Страница 18: ...assis is located on the front of the chassis Air is pulled into the chassis and pushed toward the fans which are built in Hot air exhausts from the rear of the chassis See Figure 4 on page 7 Figure 4...

Страница 19: ...ge Operating Range Internal 150 W 1 8 A maximum 50 60 Hz nominal 100 240 VAC A detachable AC power cord is supplied with the AC power supplies The coupler is type C13 as described by International Ele...

Страница 20: ...also has the option of supporting two multiservice daughter cards for 4 KHz or high quality analog audio or interrange instrumentation group IRIG signals See CTP151 Multiservice Interface Module on pa...

Страница 21: ...2 kHz reference output and configure an external clock reference the module expects an RS 422 clock input of the configured frequency on the same pins RELATED DOCUMENTATION CTP151 Multiservice Interfa...

Страница 22: ...options for 64Khz 4WTO analog high quality analog or IRIG The module also includes an external clock reference port CLK for an HD 26 connector Note that only one external clock reference is required e...

Страница 23: ...st numbered port labeled 3 is on the left and the lowest numbered port labeled 0 is at the right with the CLK port still farther to the right Figure 7 CTP151 T1 E1 Interface Module g100917 1 2 3 3 1 S...

Страница 24: ...RELATED DOCUMENTATION CTP151 Serial Interface Module 9 CTP151 Multiservice Interface Module 10 CTP151 Interface Module HD 26 Connector Cable Pinouts 33 13...

Страница 25: ...2 PART Planning System Specifications 17 Planning and Preparing the Site 19 Cable and Pinout Specifications 27...

Страница 26: ......

Страница 27: ...atform Chassis Physical Specifications Table 5 CTP151 Platform Chassis Physical Specifications Specification Category 9 9 lb 4 49 kg Weight 1 73 in 4 4 cm Height 17 36 in 44 1 cm Width 12 in 30 5 cm D...

Страница 28: ...ng environment for your device and prevent environmentally caused equipment failures Keep the area around the chassis free from dust and conductive material such as metal flakes Follow prescribed airf...

Страница 29: ...evice Table 6 CTP151 Device Environmental Tolerances Tolerance Description No performance degradation up to 2000 meters at 96 F 40 C Altitude Normal operation ensured in relative humidity range of 5 t...

Страница 30: ...recommended distances use a high quality twisted pair cable with one ground conductor for each data signal when applicable Radio frequency interference If your site is susceptible to problems with ele...

Страница 31: ...e 7 for more information about the airflow through the chassis If you are mounting a CTP151 device in a rack or cabinet with other equipment ensure that the exhaust from other equipment does not blow...

Страница 32: ...ount the device on any two post or four post rack that provides bracket holes or hole patterns spaced at 1 U 1 75 in or 4 45 cm increments and that meets the size and strength requirements to support...

Страница 33: ...d rack Rack size and strength Secure the rack to the building structure If earthquakes are a possibility in your geographical area secure the rack to the floor Secure the rack to the ceiling brackets...

Страница 34: ...assist with removing the hot air exhaust Install the CTP151 device in the cabinet in a way that maximizes the open space on the side of the chassis that has the hot air exhaust Route and dress all cab...

Страница 35: ...tion or airflow Route cables so that modules and field replaceable units are easily accessible Route cables in a logical direction to prevent loss of connectivity to other equipment in the rack associ...

Страница 36: ...Module HD 26 Connector Cable Pinouts 33 Cable Specifications for Console Connections for the CTP151 Device Table 10 on page 27 lists the specifications for the cables that connect the CTP151 device t...

Страница 37: ...he device through this port in the debugger prompt The Mini USB console port uses a Mini B plug 5 pin connector to connect to a console management device The default baud rate for the console port is...

Страница 38: ...le port on the front panel of the CTP151 to connect your laptop or PC directly to the CTP151 device If your PC or laptop has a DB 9 male connector pin you can use a combination of the RJ 45 cable and...

Страница 39: ...ble behavior Juniper Networks Technical Assistance Center JTAC can provide only limited support for issues related to unsupported hardware We strongly recommend that you use only supported USB flash d...

Страница 40: ...Transmit receive data pair 3 TRP3 4 Transmit receive data pair 3 TRP3 5 Transmit receive data pair 2 TRP2 6 Transmit receive data pair 4 TRP4 7 Transmit receive data pair 4 TRP4 8 RELATED DOCUMENTATI...

Страница 41: ...51 Platform Overview 3 RJ 45 to DB 9 Serial Port Adapter Pinout Information for a CTP151 Device The console port is an RS 232 serial interface that uses an RJ 45 connector to connect to a management d...

Страница 42: ...Device to a Management Console 66 CTP151 Interface Module HD 26 Connector Cable Pinouts IN THIS SECTION EIA 530 Connector Interface Signal Pinouts DB 25 Female DCE 34 EIA 530 Connector Interface Signa...

Страница 43: ...IA 530 Connector Interface Signal Pinouts DB 25 Female DCE Table 16 on page 34 lists the EIA 530 interface signal pinouts for the HD 26 connector to the female DB 25 connector for the CTP151 platform...

Страница 44: ...output from CTP 10 19 CC Data set ready DSR B output from CTP 22 20 RL Remote loopback RL input to CTP 21 21 TM Test mode TM output from CTP 25 22 Ground Signal ground GND 7 24 26 CD Data terminal re...

Страница 45: ...lear to send B input to CTP 13 10 Clear to send A input to CTP 5 11 Data set ready A input to CTP 6 12 Local loopback output from CTP 18 13 Transmit Data B output from CTP 14 14 Transmit Clock from DT...

Страница 46: ...CTP 2 5 Signal Out A output from CTP 5 8 Signal Out B output from CTP 12 9 Signal In B input to CTP 10 10 Signal In A input to CTP 3 11 Receive Data B output from CTP 11 14 Receive Clock B output fro...

Страница 47: ...10 Signal In A input to CTP 3 11 Transmit Data B output from CTP 11 14 Transmit Clock B output from CTP 13 15 Receive Clock B input to CTP 14 17 Receive Data B input to CTP 9 18 Ground 8 24 26 V 24 C...

Страница 48: ...gnal Pinouts RJ 45 Male Table 21 on page 39 lists the T1 E1 interface module pinout for the RJ 45 connector Table 21 T1 E1 Interface Module RJ 45 Connector Pinout Signal RJ 45 Pin RX Ring 1 RX Tip 2 3...

Страница 49: ...3 PART Safety General Safety Guidelines and Warnings 43 Module Installation Safety Guidelines and Warnings 45 Hardware Compliance and Homologation 47...

Страница 50: ......

Страница 51: ...nstall equipment in the rack from the bottom upward Doing this helps maintain the stability of the rack and reduces the chance of the rack tipping over WARNING Do not insert any metal object such as a...

Страница 52: ...emove jewelry including rings necklaces and watches before working on equipment that is connected to power lines Metal objects heat up when connected to power and ground and can cause serious burns or...

Страница 53: ...fore attaching power cables WARNING Remove jewelry including rings necklaces and watches before working on equipment that is connected to power lines Metal objects heat up when connected to power and...

Страница 54: ...RELATED DOCUMENTATION Required Tools and Safety Items for Installing CTP Modules 58 Installing a CTP Interface Module Processor Module or Clock Module 59 46...

Страница 55: ...mpatibility EMC EN 300 386 Telecom Network Equipment EMC requirements EN 55032 CISPR 32 Class A Electromagnetic compatibility of multimedia equipment Emission requirements EN 55022 CISPR 22 Informatio...

Страница 56: ...TEC SD DD EMC 221 05 OCT 16 India EMC standard IEC EN 61000 Immunity requirements RELATED DOCUMENTATION CTP151 Platform Overview 3 CTP151 Safety Guidelines and Warnings 43 48...

Страница 57: ...4 PART Installation Unpacking and Mounting the CTP151 Device 51 Installing Modules 57 Cabling 65...

Страница 58: ......

Страница 59: ...compartment and contains the quick start instructions CAUTION CTP151 device is maximally protected inside the shipping carton Do not unpack the devices until you are ready to begin installation To unp...

Страница 60: ...es without toll free numbers see https www juniper net support requesting support html Table 22 on page 52 lists the parts and their quantities in the packing list Table 22 Packing List for a CTP151 D...

Страница 61: ...tion base is moved Juniper Networks will not be held accountable for not meeting the hardware replacement service level agreement for products that do not have registered serial numbers or accurate in...

Страница 62: ...device to the rack CAUTION If you are mounting multiple devices on a rack mount a device in the bottom of the rack first and proceed to mount the rest of the devices from bottom to top To mount the de...

Страница 63: ...of the device lift the device and position it in the rack aligning the mounting bracket holes with the threaded holes in the rack or cabinet rail Align the bottom hole in both the mounting brackets wi...

Страница 64: ...screws Tighten the screws 8 Ensure that the device chassis is level by verifying that all screws on one side of the rack are aligned with the screws on the other side RELATED DOCUMENTATION Rack Requi...

Страница 65: ...ing is from left to right 0 to 1 Any single module must be installed in slot 0 and any single clock connection must come from the port in slot 0 CTP151 port numbering on the front panel for the serial...

Страница 66: ...iller panel to protect the device from dust or other foreign substances and to ensure proper device cooling CAUTION Do not discard the antistatic bag When a module is not in use store it in an antista...

Страница 67: ...t 0 3 With a Phillips screwdriver loosen the screws that secure the blank filler panel covering the empty chassis slot if present and remove the filler panel 4 Remove the module from its antistatic ba...

Страница 68: ...cent module so that proper electromagnetic interference EMI gasket compression occurs Failure to do this can make it difficult to install adjacent modules RELATED DOCUMENTATION Removing a CTP Interfac...

Страница 69: ...3 Wrap and fasten one end of the ESD grounding strap around your wrist and connect the other end to a site ESD point 4 Use a Phillips screwdriver to loosen the captive screws located at the upper rig...

Страница 70: ...onents pins leads or solder connections 8 Cover the empty chassis slot with a blank filler panel and tighten the filler panel s captive screws using a Phillips screwdriver Turn both screws several tim...

Страница 71: ...CTP151 Platform Overview 3 63...

Страница 72: ...dedicated management channel The CTP151 device has four 10 100 1000BASE T RJ 45 ports two SFP ports one management port one RJ 45 console port one Mini USB console port and one USB 3 0 port Use the ma...

Страница 73: ...h an RJ 45 connector Use the console port to connect the device to a management console or to a console server Before you begin ensure that you have a rollover cable available To connect the CTP151 de...

Страница 74: ...d manage the CTP151 device by using the RJ 45 console port or the Mini USB Type B console port The console input will be active only on one port at a time By default the RJ 45 port is set as the activ...

Страница 75: ...connector of the Mini USB cable to the host machine PC or laptop 2 Connect the Mini USB Type B 5 pin connector of the Mini USB cable to the Mini USB Type B console port labeled CON on the CTP151 devic...

Страница 76: ...ace module push the serial HD 26 cable into the module and tighten the thumb screws 3 Gently pull the cable to confirm that it is inserted correctly For more information about CTP151 cable and pinout...

Страница 77: ...5 PART Configuration Accessing the CTP151 Platform 73 Powering On and Initially Configuring the CTP151 Device 75...

Страница 78: ......

Страница 79: ...sole Before you begin connecting a CTP151 device to a console management device you must ensure that the HyperTerminal properties of the serial port on the console management device are set as follows...

Страница 80: ...address on the front panel of the CTP151 chassis 2 Connect the other end of the cable to the appropriate Ethernet network for an out of band connection CAUTION Do not change the IP address for the Et...

Страница 81: ...d to a power source For specifications on the electrical requirements for the device see CTP151 Platform Chassis Physical Specifications on page 17 CAUTION Evaluate the overall loading of the branch c...

Страница 82: ...d the CTPOS software on the internal SSD To bring up the CTP151 device with CTPOS on the internal SSD using a USB storage device 1 Download and copy the CTPOS software USB installation image to a USB...

Страница 83: ...ctp and the default password for the ctp_cmd user account is ctp_cmd You can change the default passwords later Supported protocol or protocols 0 IPv4 only 1 IPv6 only or 2 IPv4 and IPv6 Enter the app...

Страница 84: ...IPv6 Only 2 IPv4 IPv6 Please select your option rtn for 0 There are 2 ethernet devices available for use The default device is the device through which the default gateway can be accessed Ctp circuit...

Страница 85: ...storage Backing up usr local to nonvolatile storage Setting up date time Setting the date GMT Please input the year 2008 2020 return for 2010 Setting the date GMT Please input the month 1 12 return fo...

Страница 86: ...elect 5 Node Operations 3 From the Node Operations Menu select 10 Powerdown Node 4 Monitor the console output during shutdown and look for the following message reboot Power down 5 Turn off the power...

Страница 87: ...6 PART Maintenance Maintaining Components 83 Product Reclamation and Recycling 87 Contacting Customer Support and Returning the Chassis or Components 89...

Страница 88: ......

Страница 89: ...adjustable wrench Antistatic wrist strap Antistatic bags or other protective packaging to hold components Plastic boots or other protective covers for fiber optic connectors RELATED DOCUMENTATION Sto...

Страница 90: ...aintaining the CTP151 Device 83 Cleaning the CTP151 Platform 84 Cleaning the CTP151 Platform Dust is attracted to the area where the air intake vents are located Clean the area with a dry cloth every...

Страница 91: ...the chassis Before removing the device from a rack Ensure that the rack or cabinet is stable and secured to the building Ensure that there is enough space to place the removed device in its new locati...

Страница 92: ...will need them when you reinstall the chassis 3 Lift the chassis from the rack and carefully move the chassis to its new location RELATED DOCUMENTATION CTP151 Safety Guidelines and Warnings 43 Mounti...

Страница 93: ...mechanisms for the recycling and reuse of their products The RoHS Directive restricts the use of certain substances that are commonly found in electronic products today Restricted substances include h...

Страница 94: ...cled recovered or disposed of in a responsible manner Our packaging is designed to be recycled and should be handled in accordance with your local recycling policies RELATED DOCUMENTATION Returning a...

Страница 95: ...Determine the serial number of the device or component For instructions see Locating the Chassis Serial Number ID Label on a CTP151 Device on page 90 2 Obtain a Return Materials Authorization RMA num...

Страница 96: ...Authorization RMA from the Juniper Networks Technical Assistance Center JTAC After locating the serial number of the device or component you want to return open a service request with Juniper Network...

Страница 97: ...evice or Component for Shipping 91 Packing a CTP151 Device or Component for Shipping If you are returning a CTP151 device or component to Juniper Networks for repair or replacement pack the item as de...

Страница 98: ...ce 8 If you are returning accessories or FRUs with the device pack them as instructed in Packing a CTP151 Device or Component for Shipping on page 91 9 Replace the accessory box on top of the packing...

Страница 99: ...g tape Write the RMA number on the exterior of the box to ensure proper tracking RELATED DOCUMENTATION Returning a CTP151 Device or Component for Repair or Replacement 89 Contacting Customer Support t...

Страница 100: ...7 PART Troubleshooting Troubleshooting Hardware and Power Failures 97...

Страница 101: ......

Страница 102: ...t normal operation LEDs are the alarm indicators on the device Alarm Seriousness of the alarm The level of severity can be either major red or minor yellow Minor yellow or amber Indicates a noncritica...

Страница 103: ...view 3 LED Details of CTP151 Platform 5 CTP151 Platform Does Not Power On Problem Description Symptoms Device is not receiving power Module s power supply has malfunctioned Power source cannot handle...

Страница 104: ...ost Solution 1 Verify that power connections are properly attached 2 Verify that device is receiving power 3 Look to see whether or not the LEDs are lit 4 Run diagnostics using the CLI 5 If the device...

Отзывы: