background image

How to Set Up Your CBA850 3G/4G/LTE Wireless WAN Bridge

6

Configure the CBA850 Using the First Time Setup Wizard

When you log in for the first time, you are automatically directed to the First 
Time Setup wizard, which helps you customize your CBA850. 

To configure the CBA850:

1.  To change any of the following options, follow the prompts in the wizard:

 

Administrator Password 

 

Time Zone 

 

Access point name (APN) 

 

Modem authentication 

 

Failure Check

 

WiFi network name

 

Security mode

After making the changes, review the details and record your administrator 
password.

2.  Click Apply to save your settings. 

NOTE:

  To return to the First Time Setup wizard after your initial login, 

select 

System –> Setup Wizards –> First Time Setup

 on the top 

navigation bar.

Reset the Configuration

To restore the CBA850 to its factory default settings, press and hold the 

RESET

 button on the side of the device for ten seconds. Reset returns the login 

password to the default password and resets all configuration changes.

Update the Firmware

Juniper Networks regularly creates new firmware packages. You might need to 
update the firmware to use the CBA850 with new modems and to access the 
latest features.

To update the firmware:

1.  Log in to the administration pages. You might have changed the Administrator 

Password when you used the First Time Setup wizard. 

2.  Select

 System –> System Control –>  System Firmware

.

3.  Find the Firmware Upgrade section. This displays the current firmware version 

that is installed and indicates if an updated firmware is available.

4.  Download the latest firmware to your desktop from the Juniper Customer 

Support website: 

http://www.juniper.net/support/downloads/

. Log in using 

your Juniper Networks support credentials. Select 

By Series –> CBA Series  

–> CBA850

 and download the file under the 

Software

 tab. 

NOTE:

  To take a backup of the configuration settings before upgrading 

the firmware, click 

Download Settings

 under System Config Save/

Restore.

5.  Click 

Manual Firmware Upload

. In the Firmware Upgrade screen. The 

Manual Firmware Upload dialog box is displayed.

6.  Select the firmware file that you downloaded in step 4 and click 

Begin 

Firmware Upgrade

. The upgrade process will take several minutes to 

complete.

Содержание CBA850

Страница 1: ...ess and control the network at remote locations when connectivity is lost or when the primary connection fails The following models of CBA850 are available CBA850 without an integrated modem CBA850LPE VZ with an integrated Verizon modem CBA850LP3 EU with an integrated EU modem Package Contents g009233 Warranty and Registration Information End User License Agreement Safety Guide Quick Start Guide P...

Страница 2: ...ting External USB Modem Green Connected Blinking green Connecting Amber Not active might be engaged in failover process Blinking amber Connection error Blinking red Modem resetting g009235 Power status LED Modem signal strength LED State Modem signal strength Blinking indicates bar Power Status Blue Primary connection is 4G Green Primary connection is 3G Amber Issue detected Top Panel Front Panel ...

Страница 3: ...ng the modem cover and pull out the integrated modem g009242 2 Insert the SIM card into the slot marked SIM 1 use the other slot SIM 2 for a secondary or backup SIM g009243 Gold contacts face down NOTE Alternately you can also connect a Juniper Networks business grade or USB wireless broadband data modem with an active subscription ...

Страница 4: ...h the antennas to the MAIN and AUX terminals finger tight only g009240 5 Connect the power supply adapter to the DC power port on the device and to a power source NOTE Alternately you can also connect a POE enabled RJ 45 cable to the LAN 2 port g009238 Reset Modem cover screw LAN port 2 Power over Ethernet Console port DC power port LAN port 1 Power switch ...

Страница 5: ...g at locations where ambient temperatures exceed 40 C 104 F is not recommended g009241 Access the Administration Pages The CBA850 can be used immediately without any configuration changes If you want to configure any of the advanced features log in to the administration pages To access the administration pages 1 Open a browser window and type cp or 192 168 0 1 in the address bar Press Enter 2 When...

Страница 6: ...e the Firmware Juniper Networks regularly creates new firmware packages You might need to update the firmware to use the CBA850 with new modems and to access the latest features To update the firmware 1 Log in to the administration pages You might have changed the Administrator Password when you used the First Time Setup wizard 2 Select System System Control System Firmware 3 Find the Firmware Upgra...

Страница 7: ...0 MHz SAFETY AND HAZARDS Under no circumstances should the CBA850 device be used in any areas a where blasting is in progress b where explosive atmospheres may be present or c that are near i medical or life support equipment or ii any equipment which may be susceptible to any form of radio interference In such areas the CBA850 device MUST BE POWERED OFF AT ALL TIMES since the device otherwise cou...

Страница 8: ...ogo the Junos logo and JunosE are trademarks of Juniper Networks Inc All other trademarks service marks registered trademarks or registered service marks are the property of their respective owners Juniper Networks assumes no responsibility for any inaccuracies in this document Juniper Networks reserves the right to change modify transfer or otherwise revise this publication without notice Part Nu...

Отзывы: