background image

.01.

If the device has been exposed to temperature changes due to environmental changes, 

do not switch it on immediately. The arising condensation could damage the device. 

Leave the device switched off until it has reached room temperature.

This device falls under protection-class I. Therefore it is essential that the device be 

earthed.

The electric connection must carr y out by qualified person.

The device shall only be used with rate voltage and frequency.

Make sure that the available voltage is not higher than stated at the end of this manual.

Make sure the power cord is never crimped or damaged by sharp edges. If this would 

be the case, replacement of the cable must be done by an authorized dealer.

Always disconnect from the mains, when the device is not in use or before cleaning it. 

Only handle the power cord by the plug. Never pull out the plug by tugging the power 

cord.

During initial start-up some smoke or smell may arise. This is a normal process and 

does not necessarily mean that the device is defective, it should decrease gradually.

Please don't project the beam onto combustible substances.

Fixtures cannot be installed on combustible substances, keep more than 50cm 

distance with wall for smooth air flow, so there should be no shelter for fans and 

ventilation for heat radiation.

If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively 

replaced by the manufacturer or his ser vice agent or a similar qualified person in order 

to avoid a hazard.

This device has left the factor y in perfect condition. In order to maintain this 

condition and to ensure a safe operation, it is absolutely necessar y for the user to 

follow the safety instructions and warning notes written in this user manual.

CAU T I O N

Becareful with your operations.With a dangerous voltage you cansuffer a 
dangerous electric shock when touching wires!

IMPORTANT

Damages caused by the disregard of this user manual are not subject to warranty.
The dealer will not accept liability for any resulting defects or problems.

SAFETY INSTRUCTIONS

1

Содержание JNR mini-beam 230

Страница 1: ...JNR MINI BEAM 230 JNR 8129 PR LIGHTING LTD http www pr lighting com 1582 Xingye Avenue Nancun Panyu Guangzhou 511442 China TEL 86 20 3995 2888 ...

Страница 2: ...ay arise This is a normal process and does not necessarily mean that the device is defective it should decrease gradually Please don t project the beam onto combustible substances Fixtures cannot be installed on combustible substances keep more than 50cm distance with wall for smooth air flow so there should be no shelter for fans and ventilation for heat radiation If the external flexible cable o...

Страница 3: ...during the inspection 1 All screws for installing the devices or parts of the device have to be tightly connected and must not be corroded 2 There must not be any deformations on the housing color lenses fixations and installation spots ceiling suspension trussing 3 Mechanically moved parts must not show any traces of wearing and must not rotate with unbalances 4 The electric power supply cables m...

Страница 4: ...IN OUT Fan cooling system Constant temperature readout and management function Lamp using time readable on the display 35 45 C max ambient temperature IP20 protection rating 55dB at 3 dB rating 2 1 4 turn fastening Omega clamps 1 Safety attachment point available OSRAM 16 facet prism with 11 colors plus open 6 facet 8 facet prism with variable speed and direction Combined prism effect by 16 facet ...

Страница 5: ... Gobo 4 shake slow to fast Gobo 5 shake slow to fast Gobo 6 shake slow to fast Gobo 7 shake slow to fast Gobo 8 shake slow to fast Gobo 9 shake slow to fast Gobo 10 shake slow to fast Gobo 11 shake slow to fast Gobo 12 shake slow to fast Gobo 13 shake slow to fast Gobo 14 shake slow to fast Gobo 15 shake slow to fast Gobo 16 shake slow to fast Rot gobo wheel cont rotation slow to fast Shutter clos...

Страница 6: ...ion It s recommended to replace the units if MINI BEAM 230 2 5 Beam Angle LUX 0 0929 FC Photometric Beam Angle Data ø 0 54 ø 1 77 ø 1 06 ø 3 48 Beam Diameter m ft ø 0 8 ø 2 62 0m 2 5 10m 32 8ft FC LUX 163200 72000 39600 20m 65 6ft 15m 49 2ft DMX CHANNELS 9 10 0 255 0 255 0 255 0 255 0 4 5 9 10 14 15 19 20 24 25 29 30 34 35 39 40 44 45 49 50 54 55 59 60 64 65 69 70 74 75 79 80 84 85 89 90 94 95 99 ...

Страница 7: ... including amongst others calculating working load limits a fine knowledge of the installation material being used and periodic safety inspection of all installation material and the fixture If you lack these qualifications do not attempt the installation yourself Improper installation can result in bodily injury Be sure to complete all rigging and installation procedures before connecting the mai...

Страница 8: ... Turn Quick Lock Fasteners 1 4 Turn 1 4 Turn 08 Connect the provided XLR cable to the female 3 pin XLR output of your controller and the other side to the male 3 pin XLR input of the moving head You can chain multiple Moving head together through serial linking The cable needed should be two core screened cable with XLR input and output connectors Please refer to the diagram below DMX 512 connecti...

Отзывы: