Seite 15
v1.0
30.05.2022
Public
In the basic version, the 64 GB eMMC is partitioned as follows:
1. 37 GB - WINDOWS (C:)
2. 10 GB
– DATA (D:)
3. 12 GB
– Recovery partition
4. 0,25 GB
– EFI system partition
In the version with an additional 128GB SSD, the following partitioning is carried out:
1. [eMMC] 0,25 GB
– EFI system partition
2. [eMMC] 59 GB
– WINDOWS (C:)
3. [SSD] 96 GB
– DATA (D:)
4. [SSD] 32 GB
- Recovery partition
5.6
Touch calibration
The touchscreens are controlled and configured with the driver integrated in Windows ("Tablet PC set-
tings"). The calibration of the touch screen can also be achieved via the control panel ("Calibrate screen
for pen and finger inputs").
5.7
UPS - Uninterruptible Power Supply (optional)
On request, the devices can be supplied with a buffer battery integrated in the service shaft cover.
This buffer battery ensures the operability of the system in the event of short-term power failures. In the
event of longer power failures, the system can be shut down automatically after saving the data.
Due to its limited capacity, the UPS battery is only suitable for bridging short-term power failures.
Therefore, care should always be taken to keep the energy requirement low during battery operation.
Configuration of the battery operation is done via the power settings of Windows 10.
NOTE
Power failures during system updates can damage the operating system.
We strongly advise against installing programme updates or even system updates on battery power.
Even if the system shuts down when battery capacity is critical, it cannot be
guaranteed that updates have already been completely installed at this time.