background image

 

Seite 1 

v1.0 

30.05.2022 

[email protected] 

 

Public 

 
 

Jungheinrich WMT 210/215 

Service manual 

 

 

Содержание WMT 210

Страница 1: ...Seite 1 v1 0 30 05 2022 LS Support Interfaces jungheinich de Public Jungheinrich WMT 210 215 Service manual...

Страница 2: ...lung und Entsorgung von Lithium Batterien Error Bookmark not defined 2 8 Leistungsdaten Netzteil Error Bookmark not defined 2 9 Type plate 7 WMT 210 7 WMT 215 7 3 Lieferumfang Error Bookmark not defin...

Страница 3: ...terleitung Error Bookmark not defined Adaptive Helligkeitsanpassung Error Bookmark not defined 7 Jungheinrich Image Windows Standard 10 IoT Enterprise 2019 LTSC 29 7 1 Windows Updates unter Windows 10...

Страница 4: ...fication There is no guarantee for integrity and topicality Subject to change without prior notice 1 4 Trademark All mentioned soft hardware brands descriptions are protected by the general trademark...

Страница 5: ...d during service work Appropriate measures must be taken to prevent electrostatic discharges on components The device is only to be assembled installed and operated within the permissible specificatio...

Страница 6: ...performed by the manufacturer or by ser vice personnel that has been authorised by the manufacturer 2 5 Treatment and disposal of lithium batteries The device contains a lithium battery to power the...

Страница 7: ...k 3 Serial number also as barcode above 4 WLAN MAC address also as barcode above 5 Input voltage and maximum power consumption 6 Manufacturer WMT 215 No Description 1 Feature number 2 Production year...

Страница 8: ...are intact If you find any damage the device must not be put into operation Please contact the manufacturer immediately Check the contents of the packaging for completeness with regard to your order 1...

Страница 9: ...Mount the retaining bracket see illustration position 6 on the device using the screws supplied in the following order from the inside to the outside Nord Lock washer bracket Nord Lock washer Allen s...

Страница 10: ...COM1 RS232 with optional 5V power supply on pin 9 6 2 x Ethernet 10 100 1000 Mbit RJ45 7 Connection socket RP SMA male for external WLAN antenna activated via configuration center 8 3 x Type A USB 3 0...

Страница 11: ...Connection socket RP SMA male for external WLAN antenna activated via configuration center 6 Grounding PE 1 5mm flat plug contact 7 2 x Ethernet 10 100 1000 Mbit RJ45 8 COM1 RS232 with optional 5V pow...

Страница 12: ...n The device starts automatically when the voltage is applied to the Ignition input The supply voltage must be constant The permissible voltage at the IGN input corresponds to the supply voltage of th...

Страница 13: ...nctions ex factory Power button To avoid unintentional actuation press the button for at least 1 second Shift key Function for the second keyboard level The key is pressed then the corresponding funct...

Страница 14: ...configuration scripts are run 5 4 Wizard Reset With the script reset_image_for_customer in the path C Program Files Jungheinrich ResetImage the Windows Setup Wizard can be reset and restarted 5 5 Part...

Страница 15: ...al On request the devices can be supplied with a buffer battery integrated in the service shaft cover This buffer battery ensures the operability of the system in the event of short term power failure...

Страница 16: ...ure the device specific settings It can be started via the Configuration Center desktop icon Administrator rights are required to edit the settings The following chapters describe the individual menu...

Страница 17: ...t Interfaces jungheinich de Public 6 1 System Information Displays detailed system specific information among other things System overview BIOS version Serial number Model number Image version Network...

Страница 18: ...system against unauthorised access and at the same time saves energy when used in battery operated vehicles or mobile locations Applying a voltage to the enable contact when the vehicle is switched o...

Страница 19: ...Seite 19 v1 0 30 05 2022 LS Support Interfaces jungheinich de Public 6 3 Wireless Connections Configuration of the WLAN and Bluetooth radio modules...

Страница 20: ...and Restore Tools for backing up and restoring the operating system A restore point is always stored on the recovery partition during both the backup process and the rein stallation with the help of a...

Страница 21: ...board integrated in Windows osk exe another configurable on screen keyboard is available Standard layout of the on screen keyboard The following settings among others can be made for the on screen key...

Страница 22: ...Interfaces jungheinich de Public 6 6 Internal Watchdog Konfiguration des internen Watchdogs With the help of the watchdog a freeze of the operating system can be detected and the system can react auto...

Страница 23: ...Seite 23 v1 0 30 05 2022 LS Support Interfaces jungheinich de Public 6 7 Front buttons Configuration of the front buttons...

Страница 24: ...ublic 6 8 USB port blocking NOTE Only the data connection is blocked Charging of USB devices is still possible Complete deactiva tion of the front USB port is possible via the BIOS To deactivate a USB...

Страница 25: ...t be disabled The write protection is only intended for the C partition the D partition is always ex cluded from the write protection It is recommended to operate the device with the UWF enabled after...

Страница 26: ...er button is pressed NOTE If the power button is pressed for longer than 5 seconds the device is switched off hard regardless of the configuration These settings are permanently stored in the system c...

Страница 27: ...t Wedge Tool interprets all incoming data as keyboard entries via the selected COM port Optionally a pre or postcode can be configured which should be transmitted before or after the input Application...

Страница 28: ...Seite 28 v1 0 30 05 2022 LS Support Interfaces jungheinich de Public 6 12 Adaptive brightness and adjustment Default values according to illustration...

Страница 29: ...ation and UPS operation Internet Explorer start page https support rdt jungheinrich com All symbols and icons are displayed in the info area 7 1 Windows Updates Automatic Windows updates are deactivat...

Страница 30: ...front key when the Jungheinrich boot logo is displayed Enter Setup starts the BIOS setup menu 8 1 Navigation in BIOS Shift key Function for the second keyboard level The key is pressed then the corres...

Страница 31: ...ettings are adjusted to the device ex works and should only be changed by experienced users The following menu paths can be used to activate deactivate selected interfaces Interface Menu Default PXE B...

Страница 32: ...be created see next chapter 9 1 Bootable USB Assistant Requirements USB stick with at least 16 GB storage space Administrative permissions PC with Microsoft Windows 10 or higher Bootable USB Wizard to...

Страница 33: ...e USB stick to be used from the drop down menu Then select the image file to be installed on the device 4 Continue with Next and check the settings before completing the process with Finish The USB st...

Страница 34: ...beforehand so a keyboard should be connected to the de vice NOTE At the time of reinstallation only the boot USB stick should be connected directly to the device Do not use a USB hub but connect the...

Страница 35: ...Seite 35 v1 0 30 05 2022 LS Support Interfaces jungheinich de Public 10 Change history Date Description Version 30 05 2022 First Version 1 0...

Отзывы: