Jung TK AS AL 114 Скачать руководство пользователя страница 22

 

22 

Explanation of terms and definitions 

 

AS address 

Every outdoor station is assigned with an 

outdoor station  

address. 

The address enables the differentiation between the 

various installed outdoor station. Selective communication or door 
release of e.g. main- or side entrance can be realised.

 

Ready for operation   Incoming door call - You can hear a ring tone and the LED at the 

communication button flashes. You can activate a communication 
with the outdoor station by means of  a short push of the commu-
nication button. 

Hands-free operation  
(Full duplex) 

Simultaneous communication in both directions. 

Door call 
 

 

You release a door call at the assigned indoor station by means of 
pushing the bell button. A bell button can release a door call at 
two indoor stations (parallel call).  

Internal call 

An indoor station can call another assigned indoor station for an 
internal communication.   

Automatic light 
switching 
 

Programming at the  
outdoor station. 

The light will be switched depending on the ambient brightness 
when you push the bell button of the outdoor station. The limited 
brightness value is adjustable. 

Light switching 

The function button of the indoor station is assigned with the func-
tion "light switching" (factory setting). A bell button of the outdoor 
station will switch the light, if the bell button is not assigned to an 
indoor station. 

Light switching  
function 
 

 
Programming at the pow-
er supply and control unit. 

This door release button of the indoor station can be assigned 
with a second function, when the light switching function is acti-
vated: You first have to push the communication button before you 
can release the door with the door release button. 
Without pushing the communication button you will switch the light 
with the door release button. 

Parallel call 

A second indoor station can be programmed to a bell button of the 
outdoor station. 

Parallel function 
 
 

Multiple indoor station can respond to one bell button of the out-
door station or the floor bell button. Each further indoor station 
respond just as the first indoor station. 

Programming mode 

The system has to be in programming mode to assign the indoor 
stations to the desired bell buttons of the outdoor station. 

Programming lock 

Protection against unauthorized programming. With active  
programming lock no bell button can be programmed. 

Acknowledge tone 

Acoustical confirmation 

Idle mode 

The device is ready for a door call or other operation. 

Call diversion 

 

An incoming door call will be forwarded from one indoor station to 
another indoor station. The call diversion has to be activated with 
the function button. The illuminated LED of the function button 
indicates the activated call diversion. 

 
 

Содержание TK AS AL 114

Страница 1: ...4 gang TK AS AL 114 WW TK AS AL 114 TK AS ES 114 2 to 8 gang TK AS AL 128 WW TK AS AL 128 TK AS ES 128 ALBRECHT JUNG GMBH CO KG Volmestra e 1 58579 Schalksm hle Phone 49 2355 806 0 Fax 49 2355 806 189...

Страница 2: ...Programming a second indoor station to a bell button parallel call 16 Deleting the programming 17 Parameters 18 Settable parameters 18 Setting and blocking OS address 18 Setting and cancelling a prog...

Страница 3: ...0 must be observed separate cabling for high and low voltage lines minimum distance of 10 cm for joint cabling arrangements use of separators between high and low voltage lines in joint cable ducts us...

Страница 4: ...ton acoustic status indication if system is occupied existing communication automatic call cut off durable energy saving LEDs for labelling illumination fault analysis due to different flashing of the...

Страница 5: ...iption plate Screw Screw Terminals Pluggable EEPROM board DIP switch Loudspeaker Mounting hole Bell button Cable entry Microphone hole Light sensor Terminal description Faceplate Inscription plate ill...

Страница 6: ...Wiring example 2 wire technique Please observe cable length and loop resistance Indoor station Indoor station Outdoor station Power supply control unit Floor bell button Floor bell button Door releas...

Страница 7: ...relay TK TR 24 EB Floating relay contact Max AC 24 V 2 A of external power supply 3 wire technique Please observe cable length and loop resistance Indoor station Indoor station Outdoor station Power s...

Страница 8: ...Attach with plaster by means of using plaster straps 4 metal sheets with holes 4 screws and 4 nuts These plaster straps can be connected on the reverse side of the housing to the housing straps 3 Flu...

Страница 9: ...screw 1 after this the lower screw 2 Connect the wires Take off the connection block downwards Attach the wires to the connection block in accordance with the terminal description Plug on the connecti...

Страница 10: ...nscription field 2 inscription foil 3 gasket Close the opening with the gasket 3 Pay attention of the gasket position Closing the device Put the nameplate with the upper edge into the housing and snap...

Страница 11: ...ght switching Acoustic and optical signals pressing buttons Positive acknowledge tone Negative acknowledge tone button already programmed Ring tone from programming acknowledgement Nameplate illuminat...

Страница 12: ...n layout is changed all of the bell buttons have to be deleted All bell buttons are assigned with the light switching function DIP switch cover Open the device if necessary Remove the cover over the D...

Страница 13: ...n layout To activate the new button layout the buttons must be programmed as bell buttons as signment of an indoor station If a 2 gang or 1 gang button is to be used as a light button this button must...

Страница 14: ...the LED on the power supply and control unit is illuminated The button layout must be set before the bell buttons are programmed The programming must be deleted before a previously programmed bell but...

Страница 15: ...utdoor station and a ring tone sounds at the indoor station 1 Repeat steps until all bell buttons have been programmed 3 Finishing press briefly LED lights up Outdoor station in idle mode Programming...

Страница 16: ...ial numbers and then reprogram both serial numbers again 1 Initiation press briefly LED flashes Outdoor station in programming mode flashes programming mode of the system is switched on 2a By means of...

Страница 17: ...gramming has to be deleted 1 Initiation press briefly LED flashes Outdoor station in programming mode flashes programming mode of the system is switched on 2 Execution if bell button programmed 6s if...

Страница 18: ...At the same time when the programming block is cancelled the light switching function and talking only after incoming door call are cancelled and the acknowledge tone is reset to the factory pre setti...

Страница 19: ...e Set switch 8 to ON Nameplate illumination flashes quickly 0 125 s On 0 125 s Off 4 Apply parameter Pressing any bell button saves the desired value for the parameter being set An acknowledge tone so...

Страница 20: ...F OFF ON OFF OFF 1 1 1s 30s OFF ON OFF 2 2 2s 45s 2 2 ON ON OFF 3 3 3s 60s 3 3 OFF OFF ON 4 4 4s 75s 4 4 ON OFF ON 5 5 5s 90s 5 5 OFF ON ON 6 6 6s 105s Parameter value ON ON ON MAX MAX 7s 135s ON ON 7...

Страница 21: ...f No TK 60 FO Fault identification indication and querying Faults are signalled visually and acoustically single fault tone and continuous flashing of the light strip The fault type can be queried by...

Страница 22: ...n of the outdoor station will switch the light if the bell button is not assigned to an indoor station Light switching function Programming at the pow er supply and control unit This door release butt...

Страница 23: ...station to the same indoor station Each bell button can be assigned to a separate ring tone e g individual ring tones for each family member Automatic door release The door release relay will be acti...

Страница 24: ...y control unit than 20 Ohm Rule Turn OFF 230 V 50 Hz of the VS Connect a and b short circuit at the VS All other devices do not disturb the measuring proc ess and remain connected 20 Ohm 160 m wire le...

Страница 25: ...on humidity 0 to 80 r h Installation height Recommended 1 50 m Acceptance of guarantee We accept the guarantee in accordance with the corresponding legal provisions Please return the unit postage paid...

Отзывы: