4.3 Air-hydraulic pump JPL 15
WARNING
If multiple jacks are connected, make sure that the load
is lifted/lowered evenly. There is a danger of tipping.
Injuries might occur.
CAUTION
Only connect and shut off hydraulic hoses on depres-
surized jacks and pumps. Not under load / in working
position.
Setting the working pressure
> Connect the compressed air hose to the compressed
air connection (3).
> Connect the pressure gauge (8) to the
connections (7).
> Press the foot switch (4), read off the working
pressure from the pressure gauge (8) and set the
desired pressure via the pressure adjusting screw (6).
> Set the working pressure by turning the adjusting
screw
• Increase pressure: Turn in clockwise direction
• Reduce pressure: Turn in counterclockwise direction
> Then actuate the foot switch (5) to relieve pressure.
M+P-44A-0153
2
1
6
7
5
4
3
1
2
8
M+P-44A-0141