Finely stranded with conductor sleeve

0.5 ... 2.5 mm²

Fitting width

36 mm / 2 modules

Bus line
Rated voltage

DC 12 V SELV

Current consumption

max. 20 mA

Connection, Bus

Connection terminal

Cable length

max. 3 m

6.2 Parameter list

Settings window
Device settings

Parameters

Setting options, Basic
setting

Explanations

Manual commissioning

On, Off
Basic setting: On

Blocks manual commissioning
for all device channels. In the
"Off" setting, the device
cannot be reset to the factory
setting. 

Settings, channel

Parameters

Setting options, Basic
setting

Explanations

Manual commissioning

On, Off
Basic setting: On

Blocks manual commissioning
for the device channel. In the
"Off" setting, the device
cannot be reset to the factory
setting.

Operating mode

Roller shutter
Venetian blind
Awning
Basic setting: Roller shutter

Roller shutter
A rolling shutter or an awning
is controlled for which the
Fabric stretching function is
required.

Venetian blind
A Venetian blind is controlled.

Awning
An awning is controlled for
which the Fabric stretching
function is required.

Local Operation

On, Off
Basic setting: On

Blocks the output for operation
using the 

Prog

 button.

Transmission of blind/shutter
position > 10%

On, Off
Basic setting: Off

The current position of the
blind/shutter is always
transmitted when the
blind/shutter comes to a stop.
This parameter makes it
possible to specify that, during
travel, the position is saved
when the blind/shutter position
changes by more than 10%.
The saved value can then be
polled from the eNet server.

7/10

82581813
J:0082581813

12.03.2014

eNet

Radio blinds actuator for rail mounting

Содержание FM J 50700 REG

Страница 1: ...nnection of several motors to an output it is essential to observe the corresponding instructions of the manufacturers and to use a cut off relay if necessary The motors may be destroyed Risk of injur...

Страница 2: ...ed Slat change over time can be saved Fabric stretching for awnings Status indicator via LED Can be set with eNet server Change over time for direction change Running direction invertible Operation lo...

Страница 3: ...up live parts in the working environment Fitting the device o Mount device on DIN rail Output terminals must be at the top Connect bus line Figure 2 Connection diagram of bus line Labelling Colour Con...

Страница 4: ...de Figure 4 Operating mode switch Switch position Function PC Operating mode and parameter set with eNet server Ht Commission determine running time It Commission determine slat time O Blind mode of o...

Страница 5: ...mode switch figure 4 is in the Venetian blind O or rolling shutter P position o Turn the operating mode switch 2 to the I t position until the blind shutter reaches the upper end position o Turn oper...

Страница 6: ...itter all connections must be disconnected individually Resetting the device to the factory setting All connections to radio transmitters are disconnected and parameters are reset to default setting I...

Страница 7: ...the factory setting Operating mode Roller shutter Venetian blind Awning Basic setting Roller shutter Roller shutter A rolling shutter or an awning is controlled for which the Fabric stretching functio...

Страница 8: ...hannel Priority restraint 0 4 Basic setting 2 Specifies the priority for recalling and removing a scene of type Forced position for the channel Priority wind alarm 0 4 Basic setting 3 Specifies the pr...

Страница 9: ...elay contact closed This parameter can be reset to 0 for example after exchanging the load The Reset button is used to reset the counter to 0 The device must be programmed to apply the change Informat...

Страница 10: ...ly 12 V for rail mounting Art No NT 1220 REG VDC Master receiver for rail mounting Art No FM FK 32 REG eNet server Art No ENET SERVER 6 4 Warranty We reserve the right to make technical and formal cha...

Отзывы: