Radio blinds actuator for rail mounting

eNet

Radio blinds actuator for rail mounting

Art. No. : FM J 50700 REG

Operating instructions

1 Safety instructions

Electrical equipment may only be installed and fitted by electrically skilled persons.

Serious injuries, fire or property damage possible. Please read and follow manual fully.

Danger of electric shock. Always disconnect before carrying out work on the devise or
load. At the same time, take into account all circuit breakers that supply dangerous
voltage to the device or load.

Danger of electric shock. During installation and cable routing, comply with the
regulations and standards which apply for SELV circuits.

For parallel connection of several motors to an output it is essential to observe the
corresponding instructions of the manufacturers, and to use a cut-off relay if necessary.
The motors may be destroyed.

Risk of injury. Use the device only for controlling Venetian blind and roller shutter
motors or awnings. Do not use it to switch other loads.

Use only venetian blind motors with mechanical or electronic limit switches. Check the
limit switches for correct adjustment. Observe the specifications of the motor
manufacturers. Device can be damaged.

Fire hazard! Operation exclusively with the power supplies listed under accessories

These instructions are an integral part of the product, and must remain with the end
customer.

2 Device components

Figure 1: Device components

(1) Terminals
(2) Operating mode switch
(3) Button 

Prog

(4) Status LED
(5)  Bus line connection

1/10

82581813
J:0082581813

12.03.2014

Содержание FM J 50700 REG

Страница 1: ...nnection of several motors to an output it is essential to observe the corresponding instructions of the manufacturers and to use a cut off relay if necessary The motors may be destroyed Risk of injur...

Страница 2: ...ed Slat change over time can be saved Fabric stretching for awnings Status indicator via LED Can be set with eNet server Change over time for direction change Running direction invertible Operation lo...

Страница 3: ...up live parts in the working environment Fitting the device o Mount device on DIN rail Output terminals must be at the top Connect bus line Figure 2 Connection diagram of bus line Labelling Colour Con...

Страница 4: ...de Figure 4 Operating mode switch Switch position Function PC Operating mode and parameter set with eNet server Ht Commission determine running time It Commission determine slat time O Blind mode of o...

Страница 5: ...mode switch figure 4 is in the Venetian blind O or rolling shutter P position o Turn the operating mode switch 2 to the I t position until the blind shutter reaches the upper end position o Turn oper...

Страница 6: ...itter all connections must be disconnected individually Resetting the device to the factory setting All connections to radio transmitters are disconnected and parameters are reset to default setting I...

Страница 7: ...the factory setting Operating mode Roller shutter Venetian blind Awning Basic setting Roller shutter Roller shutter A rolling shutter or an awning is controlled for which the Fabric stretching functio...

Страница 8: ...hannel Priority restraint 0 4 Basic setting 2 Specifies the priority for recalling and removing a scene of type Forced position for the channel Priority wind alarm 0 4 Basic setting 3 Specifies the pr...

Страница 9: ...elay contact closed This parameter can be reset to 0 for example after exchanging the load The Reset button is used to reset the counter to 0 The device must be programmed to apply the change Informat...

Страница 10: ...ly 12 V for rail mounting Art No NT 1220 REG VDC Master receiver for rail mounting Art No FM FK 32 REG eNet server Art No ENET SERVER 6 4 Warranty We reserve the right to make technical and formal cha...

Отзывы: