If the operating mode switch is turned from the position
PC
to another operating mode, the
parameters are set to the default setting. The settings made with the eNet server will be
lost.
Mains voltage is switched off.
o
Set the operating mode switch.
5.2 Commissioning
DANGER!
Electrical shock when live parts are touched.
Electrical shocks can be fatal.
During commissioning, cover the parts carrying voltage on radio transmitters
and actuators and in their surrounding area.
i
The actuator can also be commissioned with eNet server as an alternative to the
commissioning described here.
i
Prerequisite for scenes and positioning movements is that the moving times of the
connected blind/shutter in the actuator are saved.
Saving blind/shutter running time for rolling shutters
The operating mode switch (figure 4) is in the Venetian blind
O
or rolling shutter
P
position.
o
Turn the operating mode switch (2) to the
I
t
position until the blind/shutter reaches the
upper end position.
o
Turn operating mode switch to the
H
t
position.
The blind/shutter moves downwards.
o
When the lower end position is reached, turn the operating mode switch to the
P
position.
The running time is saved and the blind/shutter moves to the upper end position.
Saving blind/shutter running time for blind
The operating mode switch (figure 4) is in the Venetian blind
O
or rolling shutter
P
position.
o
Turn the operating mode switch (2) to the
I
t
position until the blind/shutter reaches the
upper end position.
o
Turn operating mode switch to the
H
t
position.
The blind/shutter moves downwards.
o
When the lower end position is reached, turn the operating mode switch to the
I
t
position.
o
When the slats have been fully changed over, turn the operating mode switch to the
O
position.
The running times are saved and the blind/shutter moves to the upper end position.
Saving the awning running time
The operating mode switch (figure 4) is in the Venetian blind
O
or rolling shutter
P
position.
o
Turn the operating mode switch (2) to the
I
t
position until the blind/shutter reaches the
upper end position.
o
Turn operating mode switch to the
H
t
position.
o
For awnings without fabric-stretching function: When the extended lower end position is
reached, turn the operating mode switch to the
I
t
position. As soon the fabric is hanging
taut, turn the operating mode switch to the
P
position.
o
For awnings with their own fabric-stretching function: When the extended lower end
position is reached, turn the operating mode switch to the
P
position.
The running times are saved and the blind/shutter moves to the upper end position.
Connecting actuator to radio transmitters
Load is switched off.
o
Press button
Prog
for longer than 4 seconds.
5/10
82581813
J:0082581813
12.03.2014
eNet
Radio blinds actuator for rail mounting