Intended use
-
Energy sensor to determine voltage, current and energy values
-
Transfer of the measured values to the eNet server
-
Operation with power supply RMD and receiver module RMD cover or eNet server (see
accessories)
-
Installation in distribution boxes on DIN rail according to EN 60715
i
The energy sensor is not officially calibrated and may not therefore be used for invoicing
purposes.
Product characteristics
-
Detection of the current and voltage of four separate circuits
-
Separate calculation of the effective, idle, apparent power and the effective energy for each
measuring channel
-
Event or time-controlled transmission of measured value telegrams to the eNet server
-
Update of the device software
i
The parameter list is in the Internet in the documentation for this device.
Functional description
The energy sensor records and calculates various characteristic electrical values of the
connected consumers. It is possible to display these values using the visualisation of the eNet
server. All the energy sensors available in the building installation can be monitored using the
eNet server (see technical documentation of the eNet server).
Time and event-controlled data transmission
The energy sensor determines the current consumption data every 0.2 seconds. The data can
be transmitted at a configurable transmission of 1...60 minutes.
In addition, data transmission can be coupled to the change in effective output. If the effective
output exceeds a value of 1...2000 W and the deviation to the most recently transmitted value is
1...50 %, the data is transferred again, but only after at least one minute.
Default setting
Time-controlled transmission, transmission interval: 15 minutes
Event-controlled transmission:
Rel. threshold value, effective output: 10 %
Abs. threshold value, effective output: 1 W
Transferred characteristic electric values
-
Current
-
Voltage
-
Average effective output
Interval for average formation configurable between 0.2...300 s.
-
Apparent output
-
Fundamental oscillation idle power
-
Effective energy
The total effective energy is saved to power failure-proof memory.
4 Information for electrically skilled persons
4.1 Fitting and electrical connection
DANGER!
Electrical shock when live parts are touched.
Electrical shocks can be fatal.
Before working on the device, disconnect the power supply and cover up live
parts in the working environment.
Fitting the device
o
Mount device on DIN rail. Output terminals must be at the top.