Jung FM ES 36804 REG Скачать руководство пользователя страница 1

Radio energy detector, 4-channel, for rail mounting

eNet

Radio energy detector, 4-channel, for rail mounting

Art. No. : FM ES 36804 REG

Operating instructions

1 Safety instructions

Electrical equipment may only be installed and fitted by electrically skilled persons.

Serious injuries, fire or property damage possible. Please read and follow manual fully.

Danger of electric shock. Always disconnect before carrying out work on the devise or
load. At the same time, take into account all circuit breakers that supply dangerous
voltage to the device or load.

Danger of electric shock. During installation and cable routing, comply with the
regulations and standards which apply for SELV circuits.

Fire hazard! Operation exclusively with the power supplies listed under accessories

These instructions are an integral part of the product, and must remain with the end
customer.

2 Device components

Figure 1: RMD energy sensor

(1) Terminals
(2) Button 

Prog

 1...4

(3) Status-LED, red 1...4
(4)  Bus line connection

3 Function

System information

This device is a part of the eNet system.
High transmission reliability at a radio frequency of 868 MHz is achieved by the transmission
behaviour and bidirectional data transfer.
The range of a radio system depends on various external circumstances. The range can be
optimised by the choice of installation location.
You can find further information about the eNet system on our website.
The device may be operated in all EU and EFTA countries.

1/8

82582003
J:0082582003

14.03.2014

Содержание FM ES 36804 REG

Страница 1: ...andards which apply for SELV circuits Fire hazard Operation exclusively with the power supplies listed under accessories These instructions are an integral part of the product and must remain with the...

Страница 2: ...ntrolled data transmission The energy sensor determines the current consumption data every 0 2 seconds The data can be transmitted at a configurable transmission of 1 60 minutes In addition data trans...

Страница 3: ...As bus line use e g J Y St Y 2x2x0 8 o Connect the device with bus line figure 2 to the RMD reception module and power supply see instructions of RMD reception module and power supply Connecting load...

Страница 4: ...mmissioning interface Removing an energy sensor from the project o In the commissioning interface of the eNet server delete the energy sensor from the current project refer to the technical documentat...

Страница 5: ...planations Manual commissioning On Off Basic setting On Blocks manual commissioning for all device channels In the Off setting the device cannot be reset to the factory setting Transmission mode Singl...

Страница 6: ...he currently cumulated effective energy The value can be reset to 0 or set to any other value Transmission interval 1 60 min Basic setting 15 min The current consumption data is transmitted at the int...

Страница 7: ...of service Device error Measuring status no fault value is corrupted due to failure no fault Measurement active value is corrupted due to failure The sensor is not supplying valid measured values Mea...

Страница 8: ...V for rail mounting Art No NT 1220 REG VDC Master receiver for rail mounting Art No FM FK 32 REG eNet server Art No ENET SERVER 5 5 Warranty We reserve the right to make technical and formal changes...