Jung 2700AP Скачать руководство пользователя страница 3

Hand transmitter and wall transmitter:
– Light scene buttons 

Switching,
Switchover,
Value transmitter,
Light scene extension,
Light scene 

Hand transmitter:
– All On button 

Switching

Hand transmitter and wall transmitter:
– All Off button 

Switching

Hand transmitter:
– Master dimming button 

Switching,
2 x switchover,
Dimming,
Venetian blind,
2 x value transmitter,
2 x light scene extension 

Universal transmitter
– depending on operating mode set

1 x / 2 x switching,
2 x switchover,
1 x / 2 x dimming,
Venetian blind,
2 x value transmitter,
2 x light scene extension 

Radio motion detector

Switching, value transmitter

4 Information for electrically skilled persons

4.1 Fitting and electrical connection

Fitting the device

Figure 3: Connection compartment opened.

(4) Fastening holes
(5) KNX connection terminal
(6) Bus cable
(7) Cable bushing for bus cable
(8) Connection clip for 9 V block battery
(9) Button 

Enter

3/10

32532823
J0082532823

28.10.2016

 Radio Management 

Radio-KNX converter

Содержание 2700AP

Страница 1: ...tion compartment closed 1 Operation LED and reception indication Lights up green operation Flashes green receiving telegrams Flashes red telegram traffic 2 Screws for connection compartment 3 Antenna...

Страница 2: ...x 90 Brick Chipboard approx 70 Reinforced concrete approx 30 Metal Metal grid approx 10 Rain Snow approx 1 40 Intended use Integration of radio transmitters into KNX installations Surface mounting in...

Страница 3: ...iversal transmitter depending on operating mode set 1 x 2 x switching 2 x switchover 1 x 2 x dimming Venetian blind 2 x value transmitter 2 x light scene extension Radio motion detector Switching valu...

Страница 4: ...s o Record the desired state based on the following questions Question Example Where will operation be performed living room office hallway entryway What will be operated ceiling lamp wall lamp Veneti...

Страница 5: ...n physical address The programming LED goes out o Write the physical address on the device label o Load the application software into the device Assigning the radio transmitter Connection compartment...

Страница 6: ...he channel number flashes briefly in the display The radio transmitter has been saved i A channel can be operated from several radio transmitters i Cancel operation Press both buttons n and o 12 until...

Страница 7: ...opened o Connect 9 V block battery to connection clip 8 The channel display 13 lights up figure 4 o Press both buttons n and o 12 for approx 10 seconds The two decimal points light up additionally in...

Страница 8: ...CE figure 10 appears on the display All radio transmitters for this radio channel have been deleted Figure 10 Indication CE Clear Entry Deleting all radio transmitters of all radio channels Connection...

Страница 9: ...Battery type Alkaline 6LR 61 Power consumption approx 140 mW Connection Battery clip Ambient conditions Ambient temperature 5 45 C Protection class III Dimensions W H D 110 94 38 mm 5 2 Conformity Al...

Страница 10: ...UNG GMBH CO KG Volmestra e 1 58579 Schalksm hle GERMANY Telefon 49 2355 806 0 Telefax 49 2355 806 204 kundencenter jung de www jung de 10 10 32532823 J0082532823 28 10 2016 Radio Management Radio KNX...