background image

LB management

Brightness / temperature sensor Bluetooth

Operation as brightness sensor: Select the installation location on the window pane so that the
sunlight hits the sensor unobstructed even when the sun protection is active. Shadows produce
incorrect measured values.

Mounting the sensor

The contact surface of the substrate must be dry, clean and free of grease.

Figure 7: Underside of housing with adhesive pads

Apply adhesive pad (5) to underside of housing (Figure 7). Remove the protective film on
one side, place it on the underside of the sensor housing and press it down firmly. The
light guide (4) for brightness measurement must not be pasted over.

Remove the protective film from the adhesive pad, place the sensor on the surface and
press firmly.

Dismounting the sensor

Detach the sensor from the surface by rotating it alternating clockwise and counterclock-
wise.

5

Technical data

Rated voltage

DC 3 V

Battery type

1×lithium CR 2450

Brightness measurement

5 ... 80,000 lx

Temperature measurement

-5 ... +55 °C

Ambient temperature

-5 ... +55 °C

Storage/transport temperature

-20 ... +70 °C

Dimensions L×W×H

56 x 32 x 13 mm

Transmitting range

typ. 10 m

Radio frequency

2.402 ... 2.480 GHz

Transmission capacity

max. 2.5 mW, Class 2

6

Conformity

Albrecht Jung GmbH & Co. KG hereby declares that the radio system type art. no. 1792HTBT
meets the directive 2014/53/EU. You can find the full article number on the device. The com-
plete text of the EU Declaration of Conformity is available under the Internet address: 
www.jung.de/ce

7

Warranty

The warranty is provided in accordance with statutory requirements via the specialist trade.

4 / 5

82599913

11.11.2019

J0082599913

Отзывы: