5 Technical data

Rated voltage

AC 230 V ~

Mains frequency

50 / 60 Hz

Standby load: 0.1…0.5  W, depending on the cover
Ambient temperature

-20 ... +45  °C

Storage/transport temperature

-20 ... +70  °C

Total length of extension unit cable

max. 100 m

6 Troubleshooting

Operation via extension does not function properly

Cause: power and extension unit cables are routed in a shared cable. Interferences of the
power cable in the extension unit cable can lead to errors in the telegram transmission. 

Route power and extension unit cables in separate cables.
Decrease current load on the power cable.

7 Warranty

The warranty follows about the specialty store in between the legal framework as provided for
by law.

ALBRECHT JUNG GMBH & CO. KG

Volmestraße 1
58579 Schalksmühle
GERMANY

Telefon: +49 2355 806-0
Telefax: +49 2355 806-204
[email protected]
www.jung.de

4/4

82599413
J0082599413

12.03.2018

LB Management

Satellite insert 3-wire

Содержание 1723 NE

Страница 1: ... on the cover of the extension as well as on the insert and cover of the main device Different applications are possible due to various combination options of covers and inserts of the LB management system As a result these instructions only describe the essential basic functions of the extension unit operation via a push button Operations with different covers is described in the instructions for...

Страница 2: ...cally skilled persons Connecting and mounting the devices Figure 1 Connection diagram 3 wire extensions on a main device i Up to five 3 wire extensions 2 can be connected to a main device 1 figure 1 2 4 82599413 J0082599413 12 03 2018 LB Management Satellite insert 3 wire ...

Страница 3: ... or different main devices 1 can be controlled together by a 3 wire extension 2 figure 2 Figure 3 Clampable cable cross sections o Connect extension 2 according to connection diagram figure 1 and figure 2 Note clampable cable cross sections figure 3 3 4 82599413 J0082599413 12 03 2018 LB Management Satellite insert 3 wire ...

Страница 4: ...bleshooting Operation via extension does not function properly Cause power and extension unit cables are routed in a shared cable Interferences of the power cable in the extension unit cable can lead to errors in the telegram transmission Route power and extension unit cables in separate cables Decrease current load on the power cable 7 Warranty The warranty follows about the specialty store in be...

Отзывы: