background image

LB management 

KNX RF push-button

5

Insert-cover alignment

The device combination of insert and cover carries out an automatic insert-cover alignment as
soon as a cover is placed on an insert and the mains voltage is switched on.

Case 1: Insert and cover are brand new

After the insert-cover alignment, the device combination is functional in a standard configura-
tion.

Case 2: Insert is brand new and cover was already in operation

After the insert-cover alignment, the device combination is functional in a standard configura-
tion.

Case 3: Insert was already in operation and cover is brand new

After the insert-cover alignment, the device combination is functional in a standard configura-
tion.

Case 4: Insert and cover were already in operation in combination

After the insert-cover alignment, the device combination is functional. The device combination
performs its function according to its last configuration.

Case 5: Insert and cover were already in operation separately from one another

After the insert-cover alignment, the device combination is not functional. The insert-cover align-
ment identifies this case as a swapping of the covers, for example after renovating a room. The
insert-cover alignment reports an error via the status LED.

This device combination becomes functional again after programming with the ETS, a
master reset or resetting to factory settings.

Case 6: Insert is not supported by the cover

The insert-cover alignment reports an error via the status LED if the cover has been placed on
an insert not supported by the cover. The device combination is not functional.

5.1 Error message

The error reported by the insert-cover alignment is indicated by the status LED for 60 seconds.
Within these 60 seconds, the status LED flashes 3 times in pulses.

After an error has been detected during insert-cover alignment, the new assignment of a device
combination of insert and cover is only possible via the ETS. The device combination remains
without function until a new ETS is commissioned.

The 60-second signalling of the error is restarted each time the button is actuated.

The 2-gang device variant indicates the error message via the left status LED.

A firmware update is also possible in the event of an error.

6 / 12

32403803

03.11.2021

J0082403803

Содержание 10911STRF Series

Страница 1: ...fully Danger of electric shock Always disconnect before carrying out work on the device or load In so doing take all the circuit breakers into account which support dangerous voltages to the device an...

Страница 2: ...components Front view 1 channel Figure 1 and 2 channel Figure 2 Figure 1 Device components 1 channel Figure 2 Device components 2 channel 1 Rockers accessory 2 Status LED 3 Cover frame accessory 4 In...

Страница 3: ...s calling up and saving of light scenes Room temperature control Operation in cabled KNX systems via radio media coupler see chapter Accessories Operation of switching dimming DALI Venetian blind or r...

Страница 4: ...ical consumers can be set individual for each device Operation concept single area operation dual area operation Rocker function Each rocker can perform an indi vidual function Button function Two but...

Страница 5: ...ed Move Venetian blind Long press on button Stop or adjust Venetian blind Short press on button Set value e g brightness or temperature setpoint Short press on button Open scene Short press on button...

Страница 6: ...combination is not functional The insert cover align ment identifies this case as a swapping of the covers for example after renovating a room The insert cover alignment reports an error via the stat...

Страница 7: ...rd configuration see operating in structions of the insert The device combination does not transmit RF telegrams The ETS can reset the device to the delivery state with the Unload device command Statu...

Страница 8: ...ing the KNX RF push button Switching dimming Venetian blind or room temperature controller insert or 3 wire extension are mounted and connected properly see instructions of the relevant inserts The ma...

Страница 9: ...ed and ready for operation Activate programming mode Press the top right button and bottom right button simultan eously and hold for longer than 4 seconds Figure 5 The Status LED flashes red Programmi...

Страница 10: ...completed the status LED carries out its parameterised function For Touch dimmer The load must be connected before ETS commissioning Without a connected load the ETS aborts the programming process of...

Страница 11: ...reset restores the basic device setting physical address 15 15 255 firmware re mains in place The device must then be recommissioned with the ETS During secure operation A master reset deactivates dev...

Страница 12: ...m Receiver category 2 Ambient conditions Ambient temperature 5 45 C Storage transport temperature 25 70 C Relative humidity max 93 no condensation 9 Warranty The warranty is provided in accordance wit...

Отзывы: