background image

LB management 

KNX RF push-button

The status LED is switched off while the application program is programmed. As soon as
the programming is successfully completed, the status LED carries out its parameterised
function.

For "Touch dimmer": The load must be connected before ETS commissioning. Without a
connected load, the ETS aborts the programming process of the application program.

When the application program is unloaded, the status LEDs behave as in the delivery
state.

10 / 12

32403803

03.11.2021

J0082403803

Содержание 10911STRF Series

Страница 1: ...fully Danger of electric shock Always disconnect before carrying out work on the device or load In so doing take all the circuit breakers into account which support dangerous voltages to the device an...

Страница 2: ...components Front view 1 channel Figure 1 and 2 channel Figure 2 Figure 1 Device components 1 channel Figure 2 Device components 2 channel 1 Rockers accessory 2 Status LED 3 Cover frame accessory 4 In...

Страница 3: ...s calling up and saving of light scenes Room temperature control Operation in cabled KNX systems via radio media coupler see chapter Accessories Operation of switching dimming DALI Venetian blind or r...

Страница 4: ...ical consumers can be set individual for each device Operation concept single area operation dual area operation Rocker function Each rocker can perform an indi vidual function Button function Two but...

Страница 5: ...ed Move Venetian blind Long press on button Stop or adjust Venetian blind Short press on button Set value e g brightness or temperature setpoint Short press on button Open scene Short press on button...

Страница 6: ...combination is not functional The insert cover align ment identifies this case as a swapping of the covers for example after renovating a room The insert cover alignment reports an error via the stat...

Страница 7: ...rd configuration see operating in structions of the insert The device combination does not transmit RF telegrams The ETS can reset the device to the delivery state with the Unload device command Statu...

Страница 8: ...ing the KNX RF push button Switching dimming Venetian blind or room temperature controller insert or 3 wire extension are mounted and connected properly see instructions of the relevant inserts The ma...

Страница 9: ...ed and ready for operation Activate programming mode Press the top right button and bottom right button simultan eously and hold for longer than 4 seconds Figure 5 The Status LED flashes red Programmi...

Страница 10: ...completed the status LED carries out its parameterised function For Touch dimmer The load must be connected before ETS commissioning Without a connected load the ETS aborts the programming process of...

Страница 11: ...reset restores the basic device setting physical address 15 15 255 firmware re mains in place The device must then be recommissioned with the ETS During secure operation A master reset deactivates dev...

Страница 12: ...m Receiver category 2 Ambient conditions Ambient temperature 5 45 C Storage transport temperature 25 70 C Relative humidity max 93 no condensation 9 Warranty The warranty is provided in accordance wit...

Отзывы: