This device is type A, so it is not necessary its connection to an outside exhaust conduit. 
However, the device must be installed under a  cooker extractor to ensure complete removal of 
gases from the combustion. 

 
 
 
LOCATION

 

 

-

  The  gas  cooking  table  top  must  be  installed  in  a  well-ventilated  place  according  to  current 

regulations, and 

it’s not designed for fitted kitchen. 

-

  It must have sufficient ventilation to prevent the formation of unacceptable concentrations of 

products detrimental to health. 

-

  The walls adjacent to the kitchen appliances must be able to bear increases in temperature 

of 65

C. 

-

  This  appliance  must  not  be  placed  on  or  against  surfaces  made  of  inflammable  or 

combustible material. It must be kept at a minimum distance of 300 mm from the walls. 

-

  It is important to ensure that the cooker is in a levelled position to ensure its stability. 

-

 

Before  connecting  the  gas,  the  plastic  film  protecting  the  outer  surface  must  be 
removed. 

 

GAS CONNECTION 

 

-

  Connect  gas  in  compliance  with  current  safety  regulation.  The  appliances  are  prepared  for 

connection according to Norms ISO-7 or ISO 228-1. 

-

  The  general  installation  of  gas  shall  be  provided  with  a  gas  shut-off  valve  (stopcock).  It  is 

advisable  to  have  a  gas  shut-off  valve  for  each  appliance  in  order  not  to  leave  unused  the 
entire installation in the event of failure of any of the equipment in service. 

-

 

After consulting the data plate, check that the cooker is being fed with the right type of gas 
and pressure. 

-

 

Ensure  that  there  is  no  flame,  near  by,  and  also  that  all  the  gas  valves  controls  are  in  the 
closed position. 

-

 

The gas collector has an outlet gas pressure, if necessary, measure the pressure of the gas 
as close as possible to the injectors. 

-

 

Once you have connected the gas on, check to ensure that all the connections are tights. To 
do this, use a solution of water and soap. DO NOT USE A FLAME TO CHECK GAS LEAKS. 

 
 

 

 
OPERATING PRESSURES AND INJECTORS

 

 

Gas 

Pressure 

Burner / Injectors (

 mm) 

2750 

3400 

G20 (Natural Gas) 

20 mbar 

115 

125 

G30 (Butane Gas) 

28-30 mbar 

85 

93 

G31 (Propane Gas) 

37 mbar 

85 

93 

 

The power of the burners was determined on the basis of the net calorific value of the gas. 
 

Содержание 1PL006

Страница 1: ...GAS COOKING TABLE TOP MODELS 1PL006 2PL006 3PL006 1PL014 2PL014 3PL014 INSTALLATION USE AND CARE MANUAL...

Страница 2: ...ntended for the technicians of the qualified installing entities so that the installation adjustment and maintenance operations are performed correctly and in compliance with the current regulations T...

Страница 3: ...n compliance with current safety regulation The appliances are prepared for connection according to Norms ISO 7 or ISO 228 1 The general installation of gas shall be provided with a gas shut off valve...

Страница 4: ...at fixes the burner Dismantle the burner Substitute the injector that fits the required type of gas Assemble the parts by doing the operations described above in reverse order Put the appliance in its...

Страница 5: ...operation To put the burner in minimum flow rotate the knob completely to the left Fig 3 To turn the burner off rotate the respective knob clockwise until the position of closed Fig 1 PRACTICAL ADVICE...

Страница 6: ...o its deterioration Have the condition of the gas conduits checked regularly At night or when the cooker is not used for long periods of time close the gas line shut off valves If you notice the chara...

Страница 7: ...the gas tightness of the circuit The gas supply pipe to the unit must comply with legal regulatory requirements and must be examined and replaced if necessary PARTS WHICH MAY NEED TO BE REPLACED DURIN...

Страница 8: ...2014 06 Manufacturer Monteiro Electro Fabril Lda...